MX-6240N, MX-7040N (serv.man26). Section 7 Troubleshooting - Updated November 2012 - Sharp Copying Equipment Service Manual (repair manual). Page 40

Read Sharp MX-6240N / MX-7040N (serv.man26) Service Manual online

MX-7040N  TROUBLESHOOTING  7 – 40
 
L2-11
Lamp cooling fan motor trouble
 
L3-00
Scanner return trouble
 
L4-02
Paper feed motor trouble
 
L4-03
Fusing motor trouble
 
L4-06
Transfer unit lift trouble
 
L4-07
Transfer belt motor trouble
 
L4-08
Waste toner transport motor lock
Trouble content
A lock signal is detected during rotation of the fan.
A non-lock state is detected except when in rotation 
for booting.
Detail
SCU
Cause
Fan motor trouble.
Harness related to the fan motor
Circuit trouble
Check & Remedy
Check the fan motor related circuits (SCN-Mother 
PWB, SCNcnt PWB) and their harnesses and 
connectors.
Trouble content
Scanner return is not completed within the specified 
time.
Detail
SCU
Cause
Scanner unit trouble
SCU PWB trouble
Scanner control PWB trouble
Harness and connector connection trouble
Scanner home position sensor trouble
Scanner motor trouble
Check & Remedy
Use SIM1-1 to check the scan operation.
Replace the scanner unit.
Replace the SCU PWB.
Check connection of the connectors and the harness.
Replace the scanner home position sensor.
Replace the scanner motor.
Trouble content
A lock signal is not detected within the specified time 
in ON operation of the paper feed motor after 
warming-up or canceling a jam.
Detail
PCU
Cause
Paper feed motor trouble
Paper feed motor harness and connector connection 
trouble
PCU PWB trouble
Check & Remedy
Use SIM6-1 to check the operation of the paper feed 
motor.
Replace the paper feed motor.
Check connection of the paper feed motor harness 
and the connector.
Replace the PCU PWB.
Trouble content
The motor lock signal is detected during rotation of the 
fusing motor.
Detail
PCU
Cause
Fusing motor trouble
Fusing motor harness and connector connection 
trouble
PCU PWB trouble
Check & Remedy
Use SIM6-1 to check the operation of the fusing 
motor.
Replace the Fusing motor.
Check connection of the fusing motor harness and the 
connection.
Replace the PCU PWB.
Trouble content
A change in the primary transfer position sensor 
cannot be detected within the specified time in lifting 
operation of the primary transfer unit.
Detail
PCU
Cause
Transfer unit position sensor trouble
Dirt on the transfer unit position sensor.
PCU PWB trouble
Connection trouble of the connector and the harness.
Transfer unit lift mechanism trouble
Primary transfer belt unit is not installed.
Check & Remedy
Use SIM6-3 to check the separating operation of the 
transfer unit.
Install the primary transfer belt unit.
Replace the transfer unit position sensor.
Clean the transfer unit position sensor.
Replace the PCU PWB.
Check connection of the connector and the harness.
Repair the transfer unit lift mechanism.
Trouble content
The motor lock signal is detected during rotation of the 
transfer belt motor.
Detail
PCU
Cause
Transfer belt trouble.
Harness/connector trouble between the PCU PWB 
and the transfer belt motor.
Control PWB trouble.
Circuit trouble.
Check & Remedy
Use SIM25-1 to check the operation of the transfer 
belt motor.
Check the harness and the connector between the 
PCU PWB and the transfer belt motor.
Trouble content
The waste toner lock sensor is detected during 
rotation of the drum motor.
Detail
PCU
Cause
Waste toner transport motor trouble.
Waste toner transport pipe clogging
Harness/connector trouble between the PCU PWB 
and the waste toner transport motor.
Check & Remedy
Use SIM6-1 to check the operation of the waste toner 
transport motor (WTM).
Check the waste toner transport pipe for clogging.
Check the harness and the connector between the 
PCU PWB and the waste toner transport motor.
Page of 69