MX-6240N, MX-7040N (serv.man24). Section 5 Adjustments and Settings - Updated November 2012 - Sharp Copying Equipment Service Manual (repair manual). Page 87

Read Sharp MX-6240N / MX-7040N (serv.man24) Service Manual online

MX-7040N  ADJUSTMENTS AND SETTINGS  5 – 87
5)
Enter the SIM 48-1 mode.
6)
Select an adjustment item with the scroll key.
7)
Enter an image magnification ratio adjustment value with 10-
key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the image magni-
fication ratio is changed by 0.1%.
8)
Make a normal copy and obtain the copy magnification ratio.
Repeat the procedures of 1) - 8) until a satisfactory result is
obtained.
 
ADJ 17
Scan image off-center 
adjustment 
(Manual adjustment)
NOTE:
Normally if the adjustment is executed by ADJ3 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual adjustment is executed when a satis-
factory result is not obtained from the automatic adjustment
(ADJ3).
 
 
17-A
Scan image off-center adjustment (Manual 
adjustment) (Document table mode)
This adjustment must be performed in the following cases:
* When the scanner (reading) section is disassembled.
* When the scanner (reading) unit is replaced.
* When a U2 trouble occurs.
* When the scanner control PWB is replaced.
* When the EEPROM on the scanner control PWB is replaced.
1)
Make a copy of the adjustment chart (made by yourself) in the
adjustment mode (document table).
2)
Check the copy image center position.
If A - B = 
 1.0mm, the adjustment is not required.
If the above condition is not satisfied, perform the following
procedures.
3)
Enter the SIM 50-12 mode.
4)
Select the adjustment mode OC with the scroll key.
5)
Enter the adjustment value with 10-key, and press [OK] key.
The entered value is set.
When the set value is increased, the main scanning print posi-
tion is shifted to the front side by 0.1mm.
6)
Go to the copy mode, and make a copy.
Repeat the procedures of 1) - 6) until the above condition is satis-
fied.
 
 
17-B
Scan image off-center adjustment 
(Manual adjustment) (DSPF mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When the scanner (reading) section is disassembled.
* When the scanner (reading) section is replaced.
* When U2 trouble occurs.
* When the DSPF section is disassembled.
* When the DSPF unit is replaced.
CAUTION: To execute this adjustment, it is required that the
ADJ17A Scan image off-center adjustment (Document
table mode) must have been properly adjusted.
SPF (SUB)
Sub scanning direction image magnification ratio 
(Front surface)
SPFB (SUB)
Sub scanning direction image magnification ratio 
(Back surface)
B
A = B
A
B'
A' - B' =
1.0mm
A'
(100%)
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
25,*,1$/&(17(52))6(76(783
˷̚˹
˖2&
˖63)6,'(
˖63)6,'(
2.