MX-6240N, MX-7040N (serv.man17). Service Manual (Revised May 2017). - Sharp Copying Equipment Service Manual (repair manual). Page 111

Read Sharp MX-6240N / MX-7040N (serv.man17) Service Manual online

MX-7040N  ADJUSTMENTS AND SETTINGS  5 – 55
2) Set REALTIME, STOP or PRE-SCAN to adjustment item AE
STOP COPY. For contents of each setting item, refer to below.
Change the setting value of "AE WIDTH" item to "FULL" or
"PART", in some cases.
NOTE:
MODE1: High gamma (Improves the image contrast)
MODE2: Normal gamma
STOP: 
Reads the density of 3 - 7 mm area from leading edge of document,
decides the output image density according to the density of that
part. (The output image density is constant at whole area.)
REALTIME: 
Reads the density of width of the document one by one, decides
the output image density according to the density of each part of
the document. (The output image density may be not constant at
whole area.)
PRESCAN: 
Once the densities on the document surface are scanned, the out-
put image density is determined according to the average of the
scanned densities. (The output image density is even for all the
surface.)
AE WIDTH FULL: 
Document density reading area in monochrome auto mode is 3 - 7
mm (leading edge of document) x Document width. No relationship
to PRESCAN MODE
AE WIDTH PART: 
Document density reading area in monochrome auto mode is 3 - 7
mm (leading edge of document) x 100 mm (width). No relationship
to PRESCAN MODE
Operation in monochrome auto copy mode: 
When the density of the document of the read area is light, output
image density is increased by control. When the density of the doc-
ument of the read area is dark, output image density is decreased
by control.
Display/Item
Content
Set value
Default
AE_MODE
Auto exposure mode
MODE1, MODE2
MODE1
AE_STOP_COPY
Auto B/W exposure 
Stop (for copy)
REALTIME/
STOP/PRESCAN
STOP
AE_STOP_FAX
Auto B/W exposure 
Stop (for FAX)
ON/OFF
ON
AE_STOP_SCAN
Auto B/W exposure 
Stop (for scanner)
REALTIME/
STOP/PRESCAN
STOP
AE_FILTER
Auto exposure filter 
setting
SOFT
NORMAL
NORMAL
SHARP
AE_WIDTH
AE exposure width
FULL
FULL
PART
3 to 7mm
3 to 7mm
100mm
100mm
3 to 7mm
Document table/DSPF mode
Document table mode
DSPF mode
AE WIDTH = FULL
AE WIDTH = PART
AE WIDTH = PART
Document density detection area
Page of 127
Display

Click on the first or last page to see other MX-6240N / MX-7040N (serv.man17) service manuals if exist.