MX-6201N, MX-7001N (serv.man39). FUSING SECTION - Sharp Copying Equipment Service Manual (repair manual). Page 23

Read Sharp MX-6201N / MX-7001N (serv.man39) Service Manual online

MX-7001N  FUSING SECTION  O – 23
4)
Remove the screws (A), and remove the drive unit (B).
5)
Disconnect the connector (C). Remove the screws (D), and
remove the external variable motor unit (E).
6)
Remove the screws (F). Slide the gear part (G), and remove
the external variable motor (H).
(4) Fusing web cleaning motor
1)
Remove the fusing unit. (Refer to the "A. FUSING UNIT".)
2)
Remove the front cabinet upper. (Refer to the "[A] EXTERNAL
OUTFIT".)
3)
Disconnect the connector (A), and remove the harness (C)
from the clamps (B).
4)
Remove the screws (D), and remove the fusing web cleaning
motor unit (E).
5)
Remove the E-ring (F), and remove the gear (G). Remove the
screws (H), and remove the fusing web cleaning motor (I).
Parts
d
Fusing web cleaning motor
B
A
A
A
C
D
E
F
F
G
H
c
d
C
B
A
E
D
D
H
H
F
G
I
d
Page of 26
Display