U2-50
HDD section individual data check
sum error (MFP)
 
U2-80
EEPROM read/write error 
(SCU detection)
 
U2-81
Adjustment value check sum error
(SCU detection)
 
U2-90
EEPROM read/write error 
(PCU detection)
 
U2-91
Adjustment value check sum error 
(PCU detection)
 
U5-00
SPF communication trouble
 
U5-16
SPF fan motor trouble
Trouble content
MFPcnt HDD individual data check sum error 
(One-touch, group, program, etc.)
Section
MFP
Case 1
Cause
Write/read error to/from HDD
Check and 
remedy
1)
Turn OFF/ON the power to initialize the data 
related to the check sum error contents 
automatically.
2)
Since the registered contents have been 
deleted, register them again.
3)
If the trouble is not canceled, replace the 
HDD.
Case 2
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Case 3
Cause
MFPcnt PWB HDD access circuit trouble
Check and 
remedy
Replace the MFPcnt PWB.
Trouble content
1)
EEPROM version error
2)
Write error to EEPROM
Section
SCU
Case 1
Cause
EEPROM trouble, installation of EEPROM which is 
not initialized
Check and 
remedy
Check that EEPROM is properly set.
Case 2
Cause
SCU PWB EEPROM access circuit trouble
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. (If there is a printer option, 
execute SIM22-1 to save the counter data and the 
adjustment values.) Replace the SCU PWB. Use 
SIM16 to cancel the trouble.
Trouble content
EEPROM (SCU) check sum error
Section
SCU
Case 1
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Case 2
Cause
EEPROM trouble
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. (If there is a printer option, 
execute SIM22-1 to save the counter data and the 
adjustment values.) Replace the SCU PWB. Use 
SIM16 to cancel the trouble.
Case 3
Cause
SCU PWB EEPROM access circuit trouble
Check and 
remedy
Check that EEPROM is properly set.
Trouble content
EEPROM version error, write error to EEPROM
Section
PCU
Case 1
Cause
EEPROM trouble,  installation of EEPROM which 
is not initialized.
Installation of 64KBit EEPROM
Check and 
remedy
Check that EEPROM is properly set.
Check to insure that 256KBit EEPROM is installed.
Case 2
Cause
PCU PWB EEPROM access circuit trouble
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. (If there is a printer option, 
execute SIM22-1 to save the counter data and the 
adjustment values.) Replace the PCU PWB. Use 
SIM16 to cancel the trouble.
Trouble content
EEPROM (PCU) check sum error
Section
PCU
Case 1
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel the trouble.
Case 2
Cause
EEPROM trouble.
Check and 
remedy
Check that EEPROM is properly set.
Use SIM16 to cancel the trouble.
Case 3
Cause
PCU PWB EEPROM access circuit trouble
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. (If there is a printer option, 
execute SIM22-1 to save the counter data and the 
adjustment values.) Replace the PCU PWB.
Use SIM16 to cancel the trouble.
Trouble content
Communication error between the SCU and the 
DSPF, communication line test error after turning 
on the power or canceling the exclusive simulation
Section
SCU
Case 1
Cause
Malfunction due to electrical noises
Check and 
remedy
Cancel the trouble by turning OFF/ON.
Case 2
Cause
Connector and harness connection trouble or 
disconnection
Check and 
remedy
Check the connector and the harness of the 
communication line.
Case 3
Cause
Control (SCU) PWB trouble. DSPF PWB trouble
Check and 
remedy
Replace the control (SCU) PWB. Replace the 
DSPF PWB.
Trouble content
The motor lock signal is detected during rotation of 
the fan.
Section
SCU
Case 1
Cause
Fan motor trouble, harness of the fan motor 
related, circuit trouble
Check and 
remedy
Use SIM2-3 to check the operation.
Check harness, connector and fan motor related 