MX-5500N, MX-6200N, MX-7000N (serv.man47). Self diagnostics Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 29

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man47) Service Manual online

MX-7000N  SELF DIAG AND TROUBLE CODE  8 – 29
 
L4-42
Ozone fan 3 lock
 
L4-43
Paper exit cooling fan center lock
 
L4-44
Power cooling fan 2 lock
 
L6-10
Polygon motor lock detection
 
L8-01
No full wave signal
 
L8-02
Full wave signal width abnormality
 
L8-20
Power controller communication 
trouble
 
PC---
Personal counter not installed
 
U1-01
Battery trouble
 
U2-00
EEPROM read/write error 
(MFP detection)
Trouble content
When the ozone fan 3 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the paper exit cooling fan center is operated, 
the fan operation signal is not detected within the 
specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the power cooling fan 2 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
It is judged that the LSU polygon motor lock signal 
is not outputted, and the lock signal is checked 
after 15 sec from starting rotation of the polygon 
motor and it is judged that the polygon motor does 
not rotate properly.
Section
PCU
Case 1
Cause
Disconnection of the LSU connector or the LSU 
inside harness, or breakage
Check and 
remedy
Check connection of the harness and the 
connector.
Case 2
Cause
Polygon motor trouble, LSU PWB trouble
Check and 
remedy
Use SIM61-1 to check the operation of the polygon 
motor.
Replace the LSUcnt PWB. Replace the LSU.
Trouble content
No full wave signal is detected.
Section
PCU
Case 1
Cause
Harness trouble
Check and 
remedy
Check connection of the harness and the 
connector.
Case 2
Cause
Power unit trouble
Check and 
remedy
Replace the power unit.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
The full wave signal is judged as frequency 
abnormality. (The detection frequency is judged as 
65Hz or above or 45Hz or less.)
Section
PCU
Case 1
Cause
Harness trouble
Check and 
remedy
Check the harness and the connector connection.
Case 2
Cause
Power unit trouble
Check and 
remedy
Replace the power unit.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
Communication establishment error/Framing/
Parity/Protocol error
Section
MFP
Case 1
Cause
Connector connection trouble between the mother 
board PWB and the MFPcnt PWB.
MFPcnt PWB mother board connector pin 
breakage
Check and 
remedy
Check the connector connection between the 
mother board PWB and the MFPcnt PWB. Check 
grounding of the machine.
Case 2
Cause
Mother PWB trouble
Check and 
remedy
Replace the mother PWB.
Case 3
Cause
Mother PWB jumper error
Check and 
remedy
Set the mother PWB jumper to the Default side.
Trouble content
The personal counter is not installed.
Section
MFP
Case 1
Cause
The personal counter is not installed.
Check and 
remedy
Install the personal counter.
Trouble content
Backup SRAM battery voltage fall
Section
MFP
Case 1
Cause
1)
Battery life
2)
Battery circuit abnormality
Check and 
remedy
Check that the battery voltage is about 2.5V or 
above.
Trouble content
EEPROM device read/write error
Section
MFP
Case 1
Cause
EEPROM device trouble
Check and 
remedy
Replace the EEPROM device.
Case 2
Cause
EEPROM device contact failure
Check and 
remedy
Check that EEPROM device is properly inserted.
Case 3
Cause
Device access error due to electrical noises
Check and 
remedy
Replace the MFPcnt PWB.
Page of 33
Display