CCE 620R   
 
 
 
6. Connect the connector of the heater fixing plate assy (explained on Page 7) to the heater (see the figure 
below) and secure it with two M3x4 round-tipped screws.(Tight two screws) 
* Screw tightening torque: 1.0 to 1.2 N m 
* Secure the connector securely. 
* Insert the positioning dowel into the hole. 
 
 
7. Secure the heater with the M4x6 bind machine screw. 
* Screw tightening torque: 1.6 to 1.8 N m 
* The heater pawl must be inserted into the hole. 
 
 
8. Pass the heater harness through the five clamps and perform wire processing. 
 
 