MX-2640N, MX-2640NR, MX-2640FN, MX-3140N, MX-3140NR, MX-3140FN, MX-3640N, MX-3640NR, MX-3640FN (serv.man9). Service Manual Revised June 2014. - Sharp Copying Equipment Service Manual (repair manual). Page 122

Read Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man9) Service Manual online

MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 79
2) Make a duplex copy at the normal ratio on A4 paper.
3) Measure  the  images  on the co py  paper  and the original
images.
4) Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If  the  image  magnification ratio is  within  the  specified  range
(100  0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5) Enter the SIM 48-1 mode.
6) Select an adjustment item with the scroll key.
7) Enter an image magnification ratio  adjustment value with  10-
key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the image magni-
fication ratio is changed by 0.1%.
8) Make a normal copy and obtain the copy magnification ratio.
Repeat  the  procedures  of 1)   -  8) until a satisfactor y  result is
obtained.
 
ADJ 17
Scan image off-center 
adjustment 
(Manual adjustment)
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual ad justment is executed when a satis-
factory result is not  obtained from the automatic adjustment (ADJ
4).
 
17-A
Scan image off-center adjustment (Manual 
adjustment) (Document table mode)
This adjustment must be performed in the following cases:
* When the scanner (reading) section is disassembled.
* When the scanner (reading) unit is replaced.
* When a U2 trouble occurs.
* When the scanner control PWB is replaced.
* When the EEPROM on the scanner control PWB is replaced.
1) Make a copy of the adjustment chart (made by yourself) in the
adjustment mode (document table).
2) Check the copy image center position.
If A - B =  1.0mm, the adjustment is not required.
If  the  above  condition  is  not  satisfied, p erform  the  following
procedures.
Item
Display
Content
Setting 
range
Default 
value
A
CCD(MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
B
CCD(SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
C
SPF(MAIN)
RSPF document front 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
D
SPF(SUB)
RSPF document front 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
E
SPFB(MAIN)
RSPF document back 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
F
SPFB(SUB)
RSPF document back 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
SPF (SUB)
Sub scanning direction image magnification ratio 
(Front surface)
SPFB (SUB)
Sub scanning direction image magnification ratio 
(Back surface)
original
copy
10
50
100
150
200
10
50
100
150
200
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.
B
A = B
A
B'
A' - B' =
1.0mm
A'
(100%)
Page of 127
Display

Click on the first or last page to see other MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man9) service manuals if exist.