MX-2640N, MX-2640NR, MX-2640FN, MX-3140N, MX-3140NR, MX-3140FN, MX-3640N, MX-3640NR, MX-3640FN (serv.man9). Service Manual Revised June 2014. - Sharp Copying Equipment Service Manual (repair manual). Page 119

Read Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man9) Service Manual online

MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 76
7) Loosen  the  paper  feed  tray of f-center  adjustment scr ews  (2
pcs.) at the center section of the lift plate of the paper feed tray,
and change the gear unit position in the front/rear frame direc-
tion. Repeat the adjustment procedures from 4).
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual adjustment is executed when a  satis-
factory result is not obt ained from the automatic adjustment (ADJ
4).
 
ADJ 16
Scan image magnification ratio 
adjustment 
(Manual adjustment)
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual adjustment is executed when a  satis-
factory result is not obt ained from the automatic adjustment (ADJ
4).
 
16-A
Scan image magnification ratio adjustment 
(main scanning direction) (Manual 
adjustment) (Document table mode)
If  the  default  adjustment  value  of  the  scan  image  magnification
ration  adjustment  (main  scanning  direction)  of  SIM  48-1, copy
image  quality may be  degraded. Therefore, this  adjustment  must
be executed only when there is a special necessity.
This adjustment must be performed in the following cases:
* When the copy magnification ratio in the copy image main scan-
ning direction is not properly adjusted.
* When the scanner motor is replaced.
* U2 trouble has occurred.
* When the scanner control PWB is replaced.
* When the EEPROM of the scanner control PWB is replaced.
Before this  adjustment, the focus adjustment ( CCD unit installing
position adjustment) must have been completed.
1) Place  a sca le  on  the document t able  as  shown  in  the  figure
below.
2) Enter the SIM 48-1 mode.
3) Make a normal copy and obtain the copy magnification ratio.
Press  [CLOSE]  key to shif t  from th e  simulation  mode  to the
copy mode, and make a copy.
4) Check that the copy magnificati on ratio is within the specified
range (100  1.0%).
If the copy magnification ratio is within the specified range (100
 1.0%), the adjustment is completed. If the copy magnification
ratio  is not  within  the  specified  range, per form  the following
procedure.
5) Change the CCD (MAIN) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy  magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.02%.
Repeat the procedures 3) - 5) until the copy magnification ratio
is within the specified range (100  1.0%).
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.