MX-2640N, MX-2640NR, MX-2640FN, MX-3140N, MX-3140NR, MX-3140FN, MX-3640N, MX-3640NR, MX-3640FN (serv.man9). Service Manual Revised June 2014. - Sharp Copying Equipment Service Manual (repair manual). Page 121

Read Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man9) Service Manual online

MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 78
 
16-C
Scan image magnification ratio adjustment 
(main scanning direction) 
(Manual adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When U2 trouble occurs.
* When  the  copy  magnification  ratio  of the   RSPF mo de  copy
image in the main scanning direction is not proper.
* When the RSPF is disassembled.
a. Adjustment procedures
1) Place the duplex adjust ment chart shown below on the docu-
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put ma rks on both sides and
both surfaces of the paper at 10mm from each edge.
2) Make a duplex copy at the normal ratio on A4 paper.
3) Measure  the  images  on the co py  paper  and the original
images.
4) Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If  the  image  magnification ratio is  within  the  specified  range
(100  0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5) Enter the SIM 48-1 mode.
RSPF
6) Select an adjustment item  of SPF (MAIN)/SPFB (MAIN) with
the scroll key.
7) Enter an adjustment value with 10-key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased. When the adjustment value is changed
by 1, the image magnification ratio is changed by 0.02%.
8) Make a normal copy and obtain the copy magnification ratio.
Repeat  the  procedures  of 1)   -  8) until a satisfactor y  result is
obtained.
 
16-D
Scan image magnification ratio adjustment 
(sub scanning direction) (Manual 
adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the SCAN CONTROL PWB is replaced.
* When the EEPROM on the SCAN CONTROL PWB is replaced.
* When U2 trouble occurs.
* When  the  copy magnification ra tio  of  the R SPF  mode copy
image in the sub scanning direction is not proper.
* When the RSPF is disassembled.
1) Place the duplex adjustment chart shown below on the docu -
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put marks on both  sides and
both surfaces of the paper at 10mm from each edge.
A4 size
(Both the front surface
and the back surface)
10mm
10mm
Paper pass direction
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.
Item
Display
Content
Setting 
range
Default 
value
A
CCD(MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
B
CCD(SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
C
SPF(MAIN)
RSPF document front 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
D
SPF(SUB)
RSPF document front 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
E
SPFB(MAIN)
RSPF document back 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
F
SPFB(SUB)
RSPF document back 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
SPF (MAIN)
Main scanning direction image magnification ratio 
(Front surface)
SPFB (MAIN) Main scanning direction image magnification ratio 
(Back surface)
A4 size
10mm
10mm
Paper pass direction
Page of 127