  MX-FR41U (DATA SECURITY KIT)  20 – 3
5) After completion of reading, the firmware is installed (updated).
(It takes about 5 - 6 minutes.)
Display of firmware install (Update) process
- The abbreviated name of the firmware which is currently
installed (updated) is displayed sequentially.
- The screen may flash instantaneously during the install
(update) process. This is a normal operation.
6)
Check the result of install (update) of the firmware.
Use [UP] key and [DOWN] key to check the results of install
(update) of all the firmware programs.
Display of firmware update results
OK: Update success
NG: Update failed
Not Update: The update process is not executed.
Cause of Update process not executed:
The option unit for the target firmware is not connected.
7)
Turn OFF the power to terminate the boot mode.
F. Enable setting of functions
1)
Enter the product key to enable the functions.
a)
Enter the system setting mode.
b)
The machine enters the product key input mode.
c)
Enter the product key.
d)
Press the registration key.
2)
After completion of the product key input, turn OFF the power
switch on the operation panel of the machine, and turn OFF
the main power switch.
3)
Turn ON the main power switch and the power switch on the
operation panel.
G. Confirmation of function enable
Execute SIM22-10 (Machine configuration display) to check to con-
firm that the set functions are enable.
 