MX-1800N (serv.man15). Section 7 - Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp MX-1800N (serv.man15) Service Manual online

MX-1800N  SIMULATION  7 – 13
 
6-3
Purpose
Operation test/check
Function (Purpose) Used to check the operations of the primary
transfer unit and the related circuit. 
Section
Process (Transfer)
Operation/Procedure
1) Touch [EXECUTE] key.
2) The load operation is started. (Separation operation: BLACK
→ COLOR → FREE  Stops at each position for 5 sec.) During
the operation, the current position is displayed.
 
7
 
7-1
Purpose
Setting
Function (Purpose) Used to set the operating conditions of
aging.
Section
Other
Operation/Procedure
1) Select the target to be set with keys on the touch panel.
2) Touch [EXECUTE] key.
The machine is rebooted in the aging mode. 
The contents set with this simulation are retained until the
power is turned OFF. 
 
7-6
Purpose
Setting
Function (Purpose) Used to set the intermittent aging cycle.
Section
Other
Operation/Procedure
1)
Enter the intermittent aging cycle (unit: sec) with 10-key.
2)
Touch [OK] key.
The time entered in procedure 1) is set.
 
7-8
Purpose
Operation display
Function (Purpose) Used to display the warm-up time. 
Section
Fusing
Operation/Procedure
Touch [EXECUTE] key.
Counting of the warm-up time is started.
* Interruption of counting by touching [EXECUTE] key is inhibited.
 
7-9
Purpose
Operation test/check
Function (Purpose) Used to check printing in the color mode.
Section
Operation/Procedure
1)
Select a print color with keys on the touch panel.
2)
Touch [EXECUTE] key.
Printing is started in the selected color.
* If no color is specified, printing is made in all colors.
BLACK
Black mode position
Black mode position
→ COLOR mode position
→ Drum separation position
→ Shift to the black mode 
position is repeated.
COLOR
COLOR mode position
FREE
Drum separation position
AGING
Aging operation setup
INTERVAL
Intermittent setup
MISFEED DISABLE
JAM detection enable/disable setup
FUSING DISABLE
Fusing operation enable/disable setup
WARMUP DISABLE
Warm-up disable setup
DV CHECK DISABLE
DV unit detection enable/disable setup
SHADING DISABLE
Shading disable setup
CCD GAIN FREE
CCD gain adjustment free setup
0
SIMULATION NO.06-03
TEST
TRANSFER LOAD CHECK
EXECUTE
POSITION
:
1/1
CLOSE
SIMULATION NO.07-01
TEST
AGING TEST SETTING
AGING
INTERVAL
MISFEED DISABLE
FUSING DISABLE
WARMUP DISABLE
DV CHECK DISABLE
1/1
EXECUTE
0
SHADING DISABLE
CCD GAIN FREE
CLOSE
Item
Item
Set range
Default value
A
CYCLE TIME(SEC)
1 to 900
3
K
Setup/cancel of black
C
Setup/cancel of cyan
M
Setup/cancel of magenta
Y
Setup/cancel of yellow
0
A:
A㧦 3
CYCLE TIME(SEC)
SIMULATION NO.07-06
INTERVAL AGING CYCLE TIME SETUP
3
1㨪 900 㨉
OK
TEST
CLOSE
0
SIMULATION NO.07-08
TEST
WARM UP TIME DISPLAY SETTING
CLOSE
EXECUTE
0
SECONDS