Read Sharp AR-SP8 Service Manual online
AR-SP8/RP8 TEST COMMAND 6 - 3
9
02
Duplex motor reverse
rotation check (DPLX
ROT.REV.)
rotation check (DPLX
ROT.REV.)
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
04
Duplex motor rotating speed
adjustment (DPLX
ROT.SPEED)
adjustment (DPLX
ROT.SPEED)
[Function]
When this Test Command is executed, the currently set value is displayed.
Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the
machine goes into the sub code entry standby mode. The greater the set value is, the higher the
speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 6)
When this Test Command is executed, the currently set value is displayed.
Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the
machine goes into the sub code entry standby mode. The greater the set value is, the higher the
speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 6)
22
08
SPF counter display (SPF
CNT)
CNT)
[Function]
The SPF counter is displayed.
The SPF counter is displayed.
[Operation]
16
Duplex counter display
(DPLX CNT)
(DPLX CNT)
[Function]
The duplex counter is displayed.
The duplex counter is displayed.
[Operation]
22
SPF JAM counter display (S
JAM CNT)
JAM CNT)
[Function]
The SPF JAM counter is displayed.
The SPF JAM counter is displayed.
[Operation]
24
04
SPF counter clear (SPF
CLR.)
CLR.)
[Function]
When [OK/START] key is pressed, the SPF counter value is cleared to 0 and "000,000" is displayed
on the LCD.
When [OK/START] key is pressed, the SPF counter value is cleared to 0 and "000,000" is displayed
on the LCD.
[Operation]
14
SPF JAM total counter clear
(S JAM TTL CLR.)
(S JAM TTL CLR.)
[Function]
When [OK/START] key is pressed, the SPF JAM total counter value is cleared to 0, and "000,000" is
displayed on the LCD.
When [OK/START] key is pressed, the SPF JAM total counter value is cleared to 0, and "000,000" is
displayed on the LCD.
[Operation]
26
02
(R)SPF setting (SPF/RSPF)
[Function]
When this test command is executed, the current set SPF is displayed. Enter the code number corre-
sponding to the desired SPF and press [OK/START] key to save the setting.
When this test command is executed, the current set SPF is displayed. Enter the code number corre-
sponding to the desired SPF and press [OK/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
The operation is similar to test command 21-01.
Main
code
code
Sub
code
Contents
Details of function/operation
1) Initial display
09-02 DPLX ROT.REV.
EXECUTING...
1) Initial display
2) [10KEY]
3) [OK/START]
09-04 DPLX ROT.SPEED
6( 1-13)
09-04 DPLX ROT.SPEED
7( 1-13)
09-04 DPLX ROT.SPEED
7( 1-13)
1) Initial display
22-08 SPF CNT
***,***
1) Initial display
22-16 DPLX CNT
***,***
1) Initial display
22-22 S JAM CNT
***,***
1) Initial display
24-04 SPF CLR.
CLEARED 000,000
1) Initial display
24-14 S JAM TTL CLR.
CLEARED 000,000
Code number
SPF
Display item
0
SPF NO
SPF OFF
1
SPF YES
SPF ON
2
RSPF YES
RSPF ON
Click on the first or last page to see other AR-SP8 service manuals if exist.