Read Sharp AR-SP8 Service Manual online
AR-SP8/RP8 TEST COMMAND 6 - 6
50
19
Duplex copy rear edge void
adjustment (DPLX END
EDGE)
adjustment (DPLX END
EDGE)
[Function]
Used to adjust the rear edge void amount in duplex copy.
Used to adjust the rear edge void amount in duplex copy.
When this test command is executed, the current set value is displayed in 2 digits. (Center value: 50.)
The adjustment modes can be selected by pressing [
The adjustment modes can be selected by pressing [
←
/
→
] key. (Adjustment range; 1 – 99)
Enter the adjustment value and press [START] key to save the set value and make a copy. (The
paper information is cleared for every copy.)
paper information is cleared for every copy.)
When the set value is increased by 1, the void amount is increased by about 0.1mm.
∗
The initial value for duplex setting is "1to2/Short Edge" for the OC/SPF setting, or "2to2" for the
RSPF setting.
RSPF setting.
∗
When paper is discharged, the shifter is operated.
[Operation]
The operation is similar to test command 46-01.
The operation is similar to test command 46-01.
53
08
SPF scan position automatic
adjustment (SPF AUTO)
adjustment (SPF AUTO)
[Function]
Place a black chart so that it covers the SPF scan glass and the OC glass together, and close the OC
cover.
Place a black chart so that it covers the SPF scan glass and the OC glass together, and close the OC
cover.
When this test command is executed, the current adjustment value is displayed as the initial display.
∗
Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm
∗
If the values are kept as the default values, SPF scan is not performed properly. The front area of
the proper scan position may be scanned.
the proper scan position may be scanned.
In case of AUTO, press [START] key, and the mirror unit scans from the home position to the SPF
scan position with the adjustment value displayed. The SPF glass cover edge position is calculated
from the difference between the SPFG glass cover edge and the OC side document glass CCD out-
put level. If the adjustment is normal, the adjusted value is displayed. If abnormal, the error LED lights
up with the current set value displayed.
scan position with the adjustment value displayed. The SPF glass cover edge position is calculated
from the difference between the SPFG glass cover edge and the OC side document glass CCD out-
put level. If the adjustment is normal, the adjusted value is displayed. If abnormal, the error LED lights
up with the current set value displayed.
During the error LED is lighted, when [START] key is pressed again, execution is performed again.
[Operation]
The operation is similar to test command 46-01. (In MANUAL)
The operation is similar to test command 46-01. (In MANUAL)
OK/ERR display in AUTO
Main
code
code
Sub
code
Contents
Details of function/operation
Mode
Display item
Default
LED
Paper rear edge void amount
DEN-B
50
PRINT mode lamp
Print start position (Duplex back surface)
RRC-D
50
SCAN mode lamp
Mode
Display item
Default
LED
SPF scan position auto adjustment
AUTO
1
COPY mode lamp
SPF scan position manual adjustment
MANU
1
PRINT mode lamp
<When OK>
<When ERR>
53-08 SPF AUTO
AUTO 100% ** OK
53-08 SPF AUTO
AUTO 100% ** ERR