AR-SP10. Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-SP10 Service Manual online

AR-SP10/RP10 DISASSEMBLY AND ASSEMBLY
– 10 –
5. Drive frame section
1) Book sensor
2) Drive frame unit
3) Drive frame assy and drive belt
4) Pressure release solenoid
■ AR-RP10 only
Note: Make sure the spring pin A is inserted into the slot. 
Make sure that the clearance between the position at which force
is applied and the sound deadening sponge is 0.5 ~ 2 mm when
the pressure release solenoid plunger is pulled toward the sole-
noid side.