AR-RP9/SP9/AR-D33 ADJUSTMENTS 6 - 1
[6] ADJUSTMENTS
1. SPF/RSPF scan position automatic
adjustment
Place a A4 paper (white chart) so that it covers the SPF scan glass
and the OC glass together, and close the SPF/RSPF.
and the OC glass together, and close the SPF/RSPF.
When simulation 53-08 is executed, the current adjustment value is
displayed as the initial display.
displayed as the initial display.
* Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 =
about 0.127mm
* If the values are kept as the default values, SPF/RSPF scan is
not performed properly. The front area of the proper scan position
may be scanned.
may be scanned.
In case of AUTO, press [START] key, and the mirror unit scans from
the home position to the SPF/RSPF scan position with the adjust-
ment value displayed. The SPF glass cover edge position is calcu-
lated from the difference between the SPF glass cover edge and
the OC side document glass CCD output level. If the adjustment is
normal, the adjusted value is displayed. If abnormal, the error LED
lights up with the current set value displayed.
the home position to the SPF/RSPF scan position with the adjust-
ment value displayed. The SPF glass cover edge position is calcu-
lated from the difference between the SPF glass cover edge and
the OC side document glass CCD output level. If the adjustment is
normal, the adjusted value is displayed. If abnormal, the error LED
lights up with the current set value displayed.
During the error LED is lighted, when [START] key is pressed again,
execution is performed again.
execution is performed again.
Operation
The operation is similar to simulation 46-01. (In MANUAL)
OK/ERR display in AUTO (LCD Model)
2. SPF/RSPF mode sub scanning
direction magnification ratio
adjustment
adjustment
Note: Before performing this adjustment, be sure to check that the
OC mode adjustment in copying has been completed.
1) Put a scale on the original table as shown below, and make a
normal copy (100%) on the front and the back surfaces to make
a test chart.
a test chart.
Note: Since the printed copy is used as a test chart, put the scale
in paralled with the edge lines.
2) Set the test chart on the SPF and make a copy in the normal
ratio (100%). (SPF model only)
Set the test chart on the RSPF and make a duplex copy (D-D or
D-S) in the normal ratio (100%). (RSPF model only)
D-S) in the normal ratio (100%). (RSPF model only)
3) Compare the scale image and the actual image.
If necessary, perform the following adjustment procedures.
4) Execute SIM 48-05.
5) The current sub scanning direction magnification ratio correc-
tion value is displayed in two digits on the display section.
6) Enter the set value and press the [START] key.
When adjusting the RSPF, use [2-SIDED COPY] key to select
single/duplex after entering the one page print mode, perform-
ing 2-page single copy.
single/duplex after entering the one page print mode, perform-
ing 2-page single copy.
* When there is no document in SPF/RSPF, copy is inhibited.
<Adjustment specification>
Mode
Display item
Default
LED
SPF/RSPF scan
position auto
adjustment
position auto
adjustment
AUTO
1
AE mode lamp
(7Seg model)
(7Seg model)
COPY mode lamp
(LCD Model)
(LCD Model)
SPF/RSPF scan
position manual
adjustment
position manual
adjustment
MANU
1
TEXT mode lamp
(7Seg model)
(7Seg model)
PRINT mode lamp
(LCD Model)
(LCD Model)
<When OK>
<When ERR>
53-08 SPF AUTO
AUTO 100% ** OK
53-08 SPF AUTO
AUTO 100% ** ERR
Mode
Display item Default
LED
Sub scan magnification
ratio adjustment on the
surface of SPF/RSPF
document
ratio adjustment on the
surface of SPF/RSPF
document
SIDE1
50
AE mode lamp
(7Seg model)
(7Seg model)
COPY mode lamp
(LCD Model)
(LCD Model)
Sub scan magnification
ratio adjustment on the
surface of RSPF
document
ratio adjustment on the
surface of RSPF
document
SIDE2
50
PRINT mode lamp
Adjustment mode
Spec value
SIM
Set value
Setting
range
Sub scanning
direction
magnification ratio
(SPF/RSPF mode)
direction
magnification ratio
(SPF/RSPF mode)
At normal:
±1.0%
±1.0%
48-5 Add 1:
0.1% increase
Reduce 1:
0.1% decrease
0.1% decrease
1 – 99