AR-SP8/RP8  UNPACKING AND INSTALLATION  2 - 2
6) Attach the hinge guides L and R.
Attach the hinge guides L and R by fitting the pawls (two for each)
into the frame of the copier and secure them with the two screws for
each that have been removed in step 3.
7) Place the SPF/RSPF on the copier.
Gently place the SPF/RSPF on the document glass as shown in the
illustration.
At this time, be careful not to damage the original scanning section
and the OC mat.
8) Connect the SPF/RSPF with the copier using the relay harness.
<1> Connect the connector.
<2> Fit the snap band to the position shown in the illustration.
<3> Fit the grounding terminal using the supplied screw (M3 x 8).
9) Attach the rear cabinet.
Fit the four pawls located at the lower part of the rear cabinet into
the copier and secure the cabinet with the three screws.
10) Attach the rear cabinet cover.
Fit the harness of the SPF/RSPF into the cut-out portion of the
rear cabinet cover and secure the cover with the screw.
At this time, check that the three pawls of the rear cabinet cover
are fitted into the rear cabinet.
Pawls
Pawls
OC mat
Original scanning 
section
1
2
3
Pawl
Side view