AR-PE2 (serv.man6). AR-PE2 EFI Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 40

Read Sharp AR-PE2 (serv.man6) Service Manual online

3-18
3
Service Procedures
Chassis fan
The chassis fan is mounted on the side of the Fiery AR-PE2 pan and cools the heatsinks 
on the Fiery AR-PE2 board. The chassis fan cable connects to Fiery AR-PE2 board 
connector J301.
T
O
 
REMOVE
 
THE
 
CHASSIS
 
FAN
1.
Remove the chassis fan cable from board connector J301 and release the Fiery AR-PE2 
board from the three metal standoffs at the base of the chassis (see Figure 3-1 on 
page 3-2).
2.
Remove the Fiery AR-PE2 board from the chassis and place the board on an anti-static 
surface.
3.
Remove the two nuts that secure the chassis fan to the side of the Fiery AR-PE2 chassis.
4.
Remove the chassis fan from the two bolts on the side of the chassis.
Note the orientation of the fan. Set aside the nuts and fan.
T
O
 
REPLACE
 
THE
 
CHASSIS
 
FAN
1.
Position the chassis fan on the two bolts in the same orientation as when the chassis fan 
was removed.
Make sure the chassis fan blows air toward the Fiery AR-PE2 board after you reassemble 
and turn on the system.
2.
Install the two nuts on the bolts to secure the chassis fan to the chassis.
3.
Replace the Fiery AR-PE2 board in the same orientation as when it was removed.
Be careful not to damage the chassis fan cable when replacing the board.
4.
Reassemble the Fiery AR-PE2 and verify functionality as described on page 3-19.
Page of 62
Display

Click on the first or last page to see other AR-PE2 (serv.man6) service manuals if exist.