Read Sharp AR-PE2 (serv.man6) Service Manual online
3-16
3
Service Procedures
T
O
REMOVE
THE
HDD
1.
If you are removing the HDD in order to replace it with a new one, print the following
from the Functions menu (if possible):
from the Functions menu (if possible):
• Configuration page—records the customer’s current Setup configuration.
The Setup configuration will be reset to the default configuration when you install
system software on the replacement HDD.
system software on the replacement HDD.
• Font List—details what fonts are resident on the Fiery AR-PE2 HDD. Along with the
fonts that are provided on the System Software CD, the customer may have installed
additional fonts that will be deleted when the system software is installed.
additional fonts that will be deleted when the system software is installed.
2.
Shut down the Fiery AR-PE2 as described on page 3-1 and power off the copier.
3.
Remove the Fiery AR-PE2 assembly from the copier as described in the Fiery AR-PE2
Installation Manual.
Installation Manual.
4.
Remove the top plate and the cover plate to gain access to the HDD (see Figure 3-1 on
page 3-2).
page 3-2).
5.
Remove the four screws that secure the HDD to the board through the four holes on the
bottom side of the chassis.
bottom side of the chassis.
If a screw falls into the chassis, do not shake the chassis to remove the screw.
Set the screws aside.
F
IGURE
3-8
Removing the hard disk drive
6.
Remove the HDD from board connector J207.
7.
Handle the HDD with care and place it in an antistatic bag.
Do not touch the HDD with magnetic objects, such as magnetic screwdrivers. Do not
place items near the hard disk drive that are sensitive to magnets, such as credit cards and
employee ID cards. See “Proper handling” on page 3-15.
place items near the hard disk drive that are sensitive to magnets, such as credit cards and
employee ID cards. See “Proper handling” on page 3-15.
HDD
Fiery AR-PE2 board
J207