2.  Remove the connector of the separator pawl solenoid, and remove the two screws
that fix the process harness guide. (rear side)
3.  Remove the screw that fixes the separator pawl arm, once the screw has been
removed remove the separator pawl arm and the separator pawl solenoid. Replace
the separator pawl solenoid fixing plate of the separator pawl solenoid.
4.  Remove the separator pawl solenoid return spring.
5.  Remove the separator pawl shaft.