Read Sharp AR-M550 (serv.man15) Service Manual online
AR-M550/M620 SIMULATION 8 - 65
NOTE: Only the set value is changed and no printing is performed.
Operation/Procedure
(Adjustment mode selection)
1) Select the number corresponding to the copy mode to be adjusted
with 10-key. (Select one of 3 - 7.)
2) Press [START] key.
(Copy magnification ratio adjustment)
1) Select the number corresponding to the copy magnification ratio
adjustment mode to be adjusted with 10-key. (Select one of 3 - 7.)
2) Press [START] key.
3) Enter the copy magnification ratio adjustment value with 10-key.
4) Press [P] key or [START] key.
When the [START] key is pressed, copying is performed and the
adjustment value is set simultaneously.
adjustment value is set simultaneously.
The copy magnification ratio in the sub scan direction can be
adjusted by changing the scan speed (motor RPM).
adjusted by changing the scan speed (motor RPM).
The greater the value is, the greater the correction is. One step corre-
sponds to 0.1% adjustment.
sponds to 0.1% adjustment.
(Copy condition setting in this simulation)
∗
To select paper (paper feed tray), perform the following procedures.
1) Enter 0 with 10-key.
2) Press [START] key. (The mode is changed to the paper feed tray
selection mode.)
3) Enter the number corresponding to the paper feed tray of the
selected paper with 10-key. (Select one of 1 - 6.)
4) Press [START] key. (The paper feed tray is selected.)
When the total of the above set value (1 - 6) and 10 is entered, the
mode is changed to the duplex mode.
mode is changed to the duplex mode.
∗
The copy magnification ratio can be set with the following
1) Enter 2 with 10-key.
2) Press [START] key.
3) Enter the copy magnification ratio with 10-key.
4) Press [START] key.
NOTE: When [P] key is pressed after entering the adjustment value,
the adjustment value is set. When [START] key is pressed
instead, the adjustment value is set and copying is performed.
instead, the adjustment value is set and copying is performed.
Press [START] key.
Press [CUSTOM SETTINGS] key.
48
48-1
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the copy magnification ratio (in the main
scanning and the sub scanning directions).
scanning and the sub scanning directions).
Section
Optical (Image scanning)
Item
Picture quality
Item
Set
range
Default
0 TRAY SELECT
Paper feed tray selection
0 - 99
50
1 COPY START
Copy START (Default)
2 MAGNIFICATION Print magnification ratio
3 CCD (MAIN)
3 CCD (MAIN)
SCAN main scanning
magnification ratio
adjustment (CCD)
magnification ratio
adjustment (CCD)
4 CCD (SUB)
SCAN sub scanning
magnification ratio
adjustment (CCD)
magnification ratio
adjustment (CCD)
5 SPF (SUB)
SPF front surface
magnification ratio
adjustment (Sub scan)
magnification ratio
adjustment (Sub scan)
6 CIS (MAIN)
SPF back surface
magnification ratio
adjustment (CIS main scan)
magnification ratio
adjustment (CIS main scan)
7 SPF (MAIN)
SPF front surface
magnification ratio
adjustment (Main scan)
magnification ratio
adjustment (Main scan)
Normal display
NOW COPYING.
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
SIMULATION 46-45
EXP.LEVEL SETUP SCANNER(600dpi). SELECT 0-5,AND PRESS
START.
0.AUTO
50
1.1.0
50
2.2.0
50
3.3.0
50
4.4.0
50
5.5.0
50
6.AUTO(H)
50
7.1.0(H)
50
8.2.0(H)
50
9.3.0(H)
50
10.4.0(H)
50
11.5.0(H)
50
50
SIMULATION 46-45
EXP.LEVEL SETUP SCANNER(600dpi). INPUT VALUE 0-99, AND
PRESS START.
0.AUTO
1
TRAY1
TRAY1
2
TRAY2
TRAY2
3
TRAY3
TRAY3
4
TRAY4
TRAY4
5
BPT
Manual feed
6
LCC
Side LCC
Set range
25 - 400%
Select 2, and
press [START] key.
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
press [CUSTOM SETTINGS] key.
50
1
2
Select other than 0 - 2,
and press [START] key.
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
or terminate copying.
Press [START] key, or
press [CUSTOM SETTINGS] key.
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
50
5.SPF(SUB)
50
6.CIS(MAIN)
50
7.SPF(MAIN)
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT 6.LCC
(ABOVE+10: DUPLEX MODE)
Select 1, and
press [START] key.
press [START] key.
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
Click on the first or last page to see other AR-M550 (serv.man15) service manuals if exist.