AR-M550 (serv.man15). (8) Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-M550 (serv.man15) Service Manual online

AR-M550/M620  SIMULATION  8 - 11
24
1
Used to clear the misfeed counter, 
the misfeed history, the trouble 
counter, and the trouble history. (The 
counters are cleared after 
completion of maintenance.)
Data clear
Counter
2
Used to clear the number of use (the 
number of prints) of each paper feed 
section.
Data clear
Paper feed
Counter
3
Used to clear the number of use of 
the finisher, SPF, and the scan 
(reading) unit.
Data clear
Counter
4
Used to reset the maintenance 
counter.
Data clear
Counter
5
Used to reset the developer counter. 
(The developer counter of the DV 
unit which is installed is reset.)
Data clear
Counter
Developer
6
Used to reset the copy counter.
Data clear
Counter
Copy
7
Used to clear the OPC drum counter. 
(Perform this simulation when the 
OPC drum is replaced.)
Data clear
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
Counter
Photo 
conductor
9
Used clear the printer mode print 
counter and the self print mode print 
counter.
Data clear
Printer
Counter
10
Used to clear the FAX counter. (Only 
when FAX is installed)
Data clear
FAX
Counter
11
Used to reset the OPC drum rotation 
time, and the DV unit rotation time 
counter. The developer counter in 
the DV unit installed is reset.
Data clear
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
Counter
Developer
15
Used to clear the counters related to 
the scan mode and the internet FAX 
mode.
Data clear
Counter
25
1
Used to check the operations of the 
developing section (toner 
concentration, humidity and toner 
concentration sensor, humidity 
sensor). (The toner concentration 
sensor output can be monitored.)
Operation test/Check
Process 
(Developing 
section)
Operation
2
Used to make the initial setting of 
toner concentration when replacing 
developer.
Setting
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
26
2
Used to set the paper size of the 
large capacity tray (LCC) and the 
paper feed tray 2. (When the paper 
size is changed, this simulation must 
be executed to change the paper 
size in software.)
Setting
Paper feed
Setting
3
Used to set the specifications of the 
auditor. Setting must be made 
according to the auditor use 
conditions.
Setting
Auditor
Specifications
5
Used to set the count mode of the 
total counter and the maintenance 
counter.
Setting
Specifications
Counter
6
Used to set the specifications 
(paper, fixed magnification ratio, 
etc.) of the destination.
Setting
Specifications
Destination
10
Used to set the network scanner trial 
mode.
Setting
Operation
Code
Function (Purpose)
Purpose
Section
Item