AR-M550 (serv.man15). (8) Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp AR-M550 (serv.man15) Service Manual online

AR-M550/M620  SIMULATION  8 - 9
7
1
Used to set the operating conditions 
of aging.
Setting
Operation
6
Used to set the intermittent aging 
cycle.
Setting
Operation
8
Used to set the warm-up time display 
YES/NO.
Setting
Operation
8
1
Used to check and adjust the 
operations of the developing voltage 
of each color and the control circuit.
Adjustment/Operation 
test/Check
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
2
Used to check and adjust the 
operation of the main charger grid 
voltage in each printer mode and the 
control circuit.
Adjustment/Operation 
test/Check
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
6
Used to check and adjust the 
operation of the transfer charger 
voltage and the control circuit.
Adjustment/Operation 
test/Check
Image process 
(Photoconductor/
Developing/
Transfer/
Cleaning)/Transfer
17
Used to check and adjust the 
operation of the transfer charger 
voltage and the related circuit. 
(Transfer belt cleaning mode)
Operation test/Check
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
18
Used to check and adjust the voltage 
of the transfer roller cleaning/transfer 
roller print mode and the control 
circuit.
Adjustment/Operation 
test/Check
Image process 
(Photoconductor/
Developing/
Transfer/Cleaning)
19
Used to check and adjust the fusing 
bias voltage and the control circuit.
Adjustment/Operation 
test/Check
Fusing
9
1
Used to check and adjust the 
operation of the load (clutch/
solenoid) in the duplex section and 
the control circuit.
Operation test/Check
Duplex
Operation
2
Used to check the operations of the 
sensors and detectors in the duplex 
section and its control circuit.
Operation test/Check
Duplex
Operation
10
1
Used to check the operations of the 
toner motor and the related circuit.
Operation test/Check
Process 
(Developing)
Operation
2
Used to check the operations of the 
toner remaining quantity sensor and 
the related circuit.
Operation test/Check
Process 
(Developing)
Operation
13
0
Used to cancel the self-diag "U1" 
trouble. (Only when FAX is 
installed.)
Clear/Cancel (Trouble 
etc.)
FAX
Trouble
14
0
Used to cancel excluding the self-
diag U1/LOC/U2/PF troubles.
Clear/Cancel (Trouble 
etc.)
Trouble
Error
15
0
Used to cancel the self-diag "U6-09, 
F3-12, 22" (large capacity paper 
feed tray, paper feed trays 1, 2) 
troubles.
Clear/Cancel (Trouble 
etc.)
LCC
Trouble
16
0
Used to cancel the self-diag U2 
troubles.
Clear/Cancel (Trouble 
etc.)
MFP control PWB, 
PCU PWB, 
scanner control 
PWB
Trouble
17
0
Used to cancel the PF troubles 
(when the copy inhibit command 
from the host computer is received).
Clear/Cancel (Trouble 
etc.)
Communication 
unit (TEL/LIU/
MODEM etc.)
Trouble
Error
21
1
Used to set the maintenance cycle.
Setting
Specifications
Counter
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
Page of 98
Display

Click on the first or last page to see other AR-M550 (serv.man15) service manuals if exist.