AR-M351U, AR-M451U (serv.man9). Unpacking and Installation - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp AR-M351U / AR-M451U (serv.man9) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  UNPACKING AND INSTALLATION  6 - 13
7) After about 2 min, the adjustment value is stored in the
machine. Check that the mode was normally completed.
In case of an error end, remove the cause of the error, and
execute the automatic developer adjustment again.
8) Turn off/on the power, and the machine returns to the normal
mode and enters the warm-up mode.
10. Print test
1) After completion of warm-up (normal mode), select [CUSTOM
SETTINGS] 
 [Data list up] to display the menu.
2) Print [ALL SETUP LIST] to check and confirm the print quality.
3) Press the [CUSTOM SETTINGS] key again to return to the
normal menu.
11. Distortion adjustment 
(Except for North America/Europe)
Note: This adjustment must be performed after installing the
machine and its peripheral devices.
It is basically no need to perform the adjustment because it has
been made when shipping. If there should be a distortion as
shown in the figure below, perform the adjustment according to
the following procedures.
1) Use a level gauge to check to confirm that the scanner unit is
installed horizontally.
Make a copy, and if any distortion is found as shown in Fig 1
or Fig. 2, loosen the scanner fixing screw (M4 x 8) and the
cam A fixing screw (M3 x 12) to make an adjustment.
• Case of Fig. 1
Shift the cam A in the direction of A by the difference of the image.
For one scale (one groove), shift by 0.5mm.
After shifting the cam, tighten the cam A fixing screw (M3 x 12).
Make a copy again and check to confirm that there is no distortion
on the image.
• Case of Fig. 2
Shift the cam A in the direction of B by the difference of the image.
For one scale (one groove), shift by 0.5mm.
After shifting the cam, tighten the cam A fixing screw (M3 x 12).
Make a copy again and check to confirm that there is no distortion
on the image.
After adjustment, tighten the fixing screw (M3 x 12) and the scan-
ner fixing screw (M4 x 8).
Attach the decoration seal to the screw hole.
(DSPF scan position automatic adjustment)
1) Execute SIM 53-8 after completion of the distortion adjust-
ment.
2) If any distortion is made after execution of the simulation, exe-
cute the MB rail position adjustment. (Refer to "3-A OC scan
distortion adjustment (MB-B rail height adjustment)" in [8]
ADJUSTMENTS.)
12. Attach the document scanning label
13. Key sheet attachment
Attach the key sheet to the specified position on the operation
panel according to the support table below.
<North America only>
<English area other than North America>
Normal 
end:
Returns to the initial window (PRESS
START display).
Abnormal 
end: Returns to the initial window (PRESS
START display), and indicates the trouble
display (TROUBLE! EE-**).
Fixing screw
(M4x8)
First copy image
[Fig. 1]
Difference
Image
Paper
AR-M355U/
M455U
AR-M355U/
M455U + AR-P20
AR-M355U/
M455U + AR-P21
Key Sheet 
(PRINT 
display)
AR-M351U/
M451U
AR-M351U/
M451U + 
AR-NC7
AR-M351U/
M451U + 
AR-NC8
Key Sheet 
(PRINT 
display)
First copy image
[Fig. 2]
Difference
Image
Paper
Reference
Reference
6mm
15mm
Page of 14
Display