AR-M351U, AR-M451U (serv.man19). Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp AR-M351U / AR-M451U (serv.man19) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  TROUBLE CODES  11 - 10
L4
01
Content
Main motor lock detection
Detail
The motor lock signal is detected for 
1.5sec during rotation of the main 
motor.
Cause
main motor trouble
Check connection of harness between 
the PCU PWB and the main motor. 
Control circuit trouble
Check and 
remedy
Use SIM25-1 to check the main motor 
operation.
Check harness and connector between 
the PCU PWB and the main motor.
02
Content
Drum motor lock detection
Detail
The motor lock signal is detected for 
1.5sec during rotation of the drum 
motor.
Cause
Drum motor trouble
Improper connection of harness 
between the PCU PWB and the drum 
motor.
Control circuit trouble
Check and 
remedy
Use SIM6-1 to check the drum motor 
operation.
Check harness and connector between 
the PCU PWB and the drum motor.
30
Content
Controller fan motor lock detection
Detail
The motor lock signal is detected 
during rotation of the controller fan 
motor.
The motor lock signal is detected 
during rotation of the HDD fan motor.
Cause
Fan motor trouble
Improper connection of the harness 
between the controller PWB and the 
fan motor.
Control circuit trouble
Check and 
remedy
Use SIM 6-2 to check the fan motor 
operation.
Check the harness and the connector 
between the controller PWB and the 
fan motor.
L6
10
Content
Polygon motor lock detection
Detail
It is judged that the polygon motor lock 
signal is not outputted.
Lock signal is checked in the interval of 
10sec after starting the polygon motor, 
and it is judged that the polygon motor 
does not rotate normally.
Cause
The LSU connector or harness in the 
LSU is disconnected or broken.
Polygon motor trouble
Check and 
remedy
Use SIM61-1 to check the polygon 
motor operation.
Check connector and harness 
connection.
Replace LSU.
MAIN SUB
Details
L8
01
Content
No fullwave signal
Detail
Full wave signal is not detected.
Cause
The PCU PWB connector or the power 
unit harness is disconnected or broken.
PCU PWB trouble
12V power source trouble
Check and 
remedy
Check connection of the harness and 
connector.
Replace PCU PWB.
Replace the power unit.
Replace the controller connection 
mother board.
02
Content
Full wave signal width abnormality
Detail
It is judged as full wave signal 
frequency abnormality. 
(When the detection cycle is judged as 
69Hz or above or 42.5Hz or below)
Cause
The connector or harness of the PCU 
PWB and the power PWB is 
disconnected.
PCU PWB trouble
Power unit trouble
Check and 
remedy
Check connection of the harness and 
connector.
Replace the PCU PWB.
Replace the power unit. 
U1
01
Content
FAX battery abnormality
Detail
FAX backup SRAM battery voltage fall
Cause
Battery life
Battery circuit abnormality
Check and 
remedy
Check that the battery voltage is about 
2.5V or above.
Check the battery circuit. 
02
Content
RTC read abnormality 
(common with FAX, on ICU PWB)
Details
The value read from RTC on ICU PWB 
is [EE]h (abnormal).
Cause
RTC circuit abnormality
Battery voltage fall
Battery circuit abnormality
Check & 
Remedy
Set the time again with key operation, 
and check that time advances properly.
Check RTC circuit.
Check that battery voltage is about 
2.5V or above.
Check battery circuit. 
U2
00
Content
EEPROM read/write error (ICU)
Detail
EEPROM write error
Cause
EEPROM trouble
EEPROM is not initialized.
ICU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the  simulation.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.