AR-M351U, AR-M451U (serv.man19). Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-M351U / AR-M451U (serv.man19) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  TROUBLE CODES  11 - 11
U2
11
Content
Counter check sum error (ICU)
Detail
Counter data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
ICU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the  DIAG simulation.
Use DIAG (SIM16) to cancel U2 
trouble.
Replace the ICU PWB.
12
Content
Adjustment value check sum error 
(ICU)
Detail
Adjustment data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
ICU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the  simulation.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
22
Content
SRAM memory check sum error (ICU)
Detail
MFPC section SRAM memory check 
sum error
Cause
SRAM trouble
Control circuit runaway due to noises
ICU PWB SRAM access circuit trouble
Check and 
remedy
Initialize the communication 
management table registered in the 
SRAM and the FAX soft switch.
Since the registered data are deleted, 
register the data again.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
23
Content
SRAM memory individual data check 
sum error (ICU)
Detail
Check sum error for every data in the 
SRAM memory of the MFPC section
(Communication management table, 
sender registration data, etc.)
Cause
SRAM trouble
Control circuit runaway due to noises
ICU PWB SRAM access circuit trouble
Check and 
remedy
Automatically initialize the data related 
to the check sum error by turning OFF/
ON the power.
Since the registered data are deleted, 
register the data again.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
MAIN SUB
Details
U2
50
Content
HD section individual data check sum 
error (ICU)
Detail
Check sum error for every individual 
data in HD of the MFPC section (One-
touch, Group, Program, etc.)
Cause
HDD write/read error
Control circuit runaway due to noises
ICU PWB HD access circuit trouble
Check and 
remedy
Automatically initialize the data related 
to the check sum error by turning OFF/
ON the power.
Since the registered data are deleted, 
register the data again.
Use SIM 16 to cancel the U2 trouble.
Replace the HD PWB.
Replace the ICU PWB.
80
Content
EEPROM read/write error (Scanner)
Details
Scanner EEPROM write error
Cause
EEPROM abnormality
Scanner PWB EEPROM access circuit 
abnormality
Check & 
Remedy
Check that EEPROM is set properly.
Record counter/adjustment values with 
the simulation to protect the data from 
being deleted.
Cancel U2 trouble with SIM 16.
Replace scanner PWB.
81
Content
Memory check sum error (Scanner)
Details
Scanner memory check sum error
Cause
EEPROM trouble
EEPROM which is not initialized is 
installed.
Control circuit freeze by noises
Scanner PWB EEPROM access circuit 
trouble
Check & 
Remedy
Check that EEPROM is set properly.
Record counter/adjustment values with 
the simulation to protect the data from 
being deleted.
Cancel U2 trouble with SIM 16.
Replace scanner PWB.
90
Content
EEPROM read/write error (PCU)
Detail
PCU EEPROM write error
Cause
EEPROM trouble
PCU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Record counter/adjustment values with 
the simulation to protect the data from 
being deleted.
Use SIM16 to cancel U2 trouble.
Replace the Controller PWB.
91
Content
Memory check sum error (PCU)
Detail
PCU memory check sum error
Cause
EEPROM trouble
EEPROM which is not initialized is 
installed.
EEPROM is not initialized.
PCU PWB EEPROM access circuit 
trouble
Hang of control circuit due to noises
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the simulation.
Use SIM16 to cancel U2 trouble.
Replace the Controller PWB.
MAIN SUB
Details
Page of 16
Display

Click on the first or last page to see other AR-M351U / AR-M451U (serv.man19) service manuals if exist.