AR-M351U, AR-M451U (serv.man16). Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp AR-M351U / AR-M451U (serv.man16) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  ADJUSTMENTS  8 - 10
<Display values 1>
<Set values 2>
With the above + 10, the SPF enters the duplex mode (DD),
making duplex copy.
<Set values 3>
<8> Original off-center adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF scan distortion adjustment
• OC scan magnification ratio
• SPF scan lead edge adjustment
Items which must be executed after completion of this adjust-
ment.
• Nothing special
1) Set an original on the original table. 
2) Execute SIM 50-12.
3) Select the paper feed tray and the magnification ratio. 
4) After entering the adjustment value, pres START key, and
printing is started.
5) Check the off-center (distance from the paper lead edge) of
the printed copy. Repeat procedure 2 until the printed copy
satisfies the specifications.
• For the duplex mode (Single 
 Duplex), add 10 to the above set
value.
• When the print line is shifted toward a from the paper center,
decrease the value.
• When the print line is shifted toward b from the paper center,
increase the value.
<Specifications>
3. Scanner section
A. OC scan distortion adjustment 
(MB-B rail height adjustment)
• This adjustment requires a high-level preciseness.
It is easier to perform the scanner unit distortion adjustment pre-
viously described. 
Before performing this adjustment, the following adjustment must
have been completed.
• LSU right angle adjustment
1) Make a test chart as shown below. (Print a self-print pattern
71.)
2) Make a copy from the table glass, and check it. 
At that time, set the test chart correctly. If it is set in a distorted
position, the adjustment cannot be made correctly.
3) If the output value is not in the specified range, perform the fol-
lowing adjustment.
4) Remove the front cabinet in front of the scanner, and check
that installing position of the MB rail. 
5) Loosen the screw at the right of the MB rail to adjust.
<Specifications>
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
Manual feed
Set range
25 - 200%
Adjustment position
Measurem
ent 
reference
Specification
Set value
Default
Range
Original 
off-center 
SIM50-12
PLATEN
OC mode
Copy 
output 
center line
As shone in 
the table 
below.
50
0 – 99 Set value 
1: 0.1mm 
shift
SPF 
SIDE1
SPF front 
surface 
adjustment
SPF 
SIDE2
SPF back 
surface 
adjustment
a
b
Specification ± 1.5mm 
Print lead edge
2
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 0-9, AND PRESS
START.
0.TRAY SELECT 
1
   1.COPY START
2.MAGNIFICATION 
100
(ADJUSTMENT DATA)
3.PLATEN 
50
 4.SPF SIDE1 
50
 5.SPF SIDE2 
50
Machine (OC mode)
Single
±1.5mm
Duplex
±1.7mm
Overall (DSPF)
Single S - S
±2.8mm
Single D - S
±3.5mm
Duplex S - D
±3.0mm
Duplex D - D
±3.5mm
Measurement 
point
Specification
Set value
OC scan 
distortion 
adjustment
Angle 
θ
 in the 
above figure
θ
 = 90°±0.13° 1 scale = about 
0.25°shift in 
θ
Page of 17