AR-M351U/M451U, AR-M355U/M455U ADJUSTMENTS 8 - 5
When the set value is increased, the warp amount of paper is
increased. When the adjustment value is decreased, the warp
amount of paper is decreased.
increased. When the adjustment value is decreased, the warp
amount of paper is decreased.
<4> Self print lead edge adjustment
Items which must have been completed before this adjust-
ment.
ment.
• LSU right angle adjustment (If there is no distortion in self print,
the adjustment is not required.)
• Print off-center adjustment
• Resist amount adjustment
Items which must be executed after completion of this adjust-
ment.
ment.
• Front/rear and left/right void amount setting
• OC scan lead edge adjustment
• SPF scan lead edge adjustment
1) Execute SIM 50-5.
2) Set the lead edge void adjustment value (DENA) as specified
2) Set the lead edge void adjustment value (DENA) as specified
below.
(Standard set value) Paper lead edge void: 3.5mm (DENA:
35)
35)
∗
Set the adjustment value of DENA to 35. (Enter 35 as the
adjustment value of DENA, and press [P] key.)
adjustment value of DENA, and press [P] key.)
3) Check the lead edge void area on the self print pattern
(SIM67-1).
(Enter 1 and press [START] key.)
4) If the adjustment result is not satisfactory, perform the follow-
ing procedures.
∗
If the lead edge void area is not 3.5mm:
Change the adjustment value of RRCB and perform the
adjustment. (Change the adjustment value of RRCB and
press [START] key.)
(Shift for the adjustment value change: 0.1mm/step)
Change the adjustment value of RRCB and perform the
adjustment. (Change the adjustment value of RRCB and
press [START] key.)
(Shift for the adjustment value change: 0.1mm/step)
<Specification>
<5> Front/rear and left/right void amount setting
Items which must have been completed before this adjust-
ment.
ment.
• LSU right angle adjustment (If there is no distortion in self print,
the adjustment is not required.)
• Print off-center adjustment
• Resist amount adjustment
• Print lead edge adjustment
Items which must be executed after completion of this adjust-
ment.
ment.
• OC scan lead edge adjustment
• SPF scan lead edge adjustment
1) Execute SIM 50-1.
(Lead edge image loss/void area adjustment)
(Lead edge image loss/void area adjustment)
1) Set the lead edge image loss adjustment value (LEAD EDGE)
and the paper lead edge void adjustment value (DENA) as fol-
lows.
lows.
(Standard set value)
Lead edge image loss: 1.5mm (LEDA: 15)
Lead edge image loss: 1.5mm (LEDA: 15)
Paper lead edge void: 3.5mm (DENA: 35)
∗
Set LEAD to 15. (Enter 15 as the adjustment value of LEAD,
and press [P] key.) (0.1mm/step)
and press [P] key.) (0.1mm/step)
∗
Set DENA to 35. (Enter 35 as the adjustment value of
DENA, and press [P] key.) (0.1mm/step)
DENA, and press [P] key.) (0.1mm/step)
2) Make a copy at the normal ratio (100%) and check the lead
edge void area and the image loss. (Enter 100 as the set value
of the copy magnification ratio (MAGNIFICATION), and press
[START] key.)
of the copy magnification ratio (MAGNIFICATION), and press
[START] key.)
3) If the adjustment result is not satisfactory, perform the follow-
ing procedures.
∗
If the lead edge void are is not 3.5mm:
Change the adjustment value of RRCB and perform the
adjustment. (Change the adjustment value of RRCB and
press [START] key.) (1msec/step)
Change the adjustment value of RRCB and perform the
adjustment. (Change the adjustment value of RRCB and
press [START] key.) (1msec/step)
∗
If the lead edge image loss is not 1.5mm:
Change the adjustment value of RRCA and perform the
adjustment. (Change the adjustment value of RRCA and
press [START] key.)
(Shift for the adjustment value change: 0.2mm/step)
Change the adjustment value of RRCA and perform the
adjustment. (Change the adjustment value of RRCA and
press [START] key.)
(Shift for the adjustment value change: 0.2mm/step)
(Rear edge void area adjustment)
Adjust so that the rear edge void area is 3.5mm. (Change the
adjustment value of TRAIL EDGE, and press [START] key.)
adjustment value of TRAIL EDGE, and press [START] key.)
(Front/rear frame direction image loss adjustment)
Set the adjustment value of SIDE to 20. (Enter 20 as the adjust-
ment value of SIDE, and press [P] key.)
ment value of SIDE, and press [P] key.)
When the adjustment value is changed, the image position is
shifted in the front/rear frame direction.
shifted in the front/rear frame direction.
(Front/rear frame direction void area adjustment)
Adjust so that the total of the front/rear direction void areas is
7.0mm. (Change the adjustment values of FRONT/REAR, and
press [START] key.)
7.0mm. (Change the adjustment values of FRONT/REAR, and
press [START] key.)
Front frame void area = 3.5mm
Rear frame void area = 3.5mm
If, as shown above, the front and the rear void areas are not even,
use SIM 50-5 to adjust the image off-center position.
use SIM 50-5 to adjust the image off-center position.
Item
Set
range
Default
AR-M351U/
M355U
AR-M451U/
M455U
2 TRAY1
Tray 1 resist
adjustment value
adjustment value
0 - 99
65
60
3 TRAY2
Tray 2 resist
adjustment value
adjustment value
55
50
4 DESK
Desk resist
adjustment value
adjustment value
55
50
5 BPT
Manual tray resist
adjustment value
adjustment value
60
55
6 ADU
ADU resist
adjustment value
adjustment value
55
50
Set position
Specification
Set value
Self print lead
edge
adjustment
SIM 50-5
edge
adjustment
SIM 50-5
Print start
position A of
the output
pattern 1
position A of
the output
pattern 1
A = 4.0mm or less
(Lead and tail
total: 8.0mm or
less)
(Lead and tail
total: 8.0mm or
less)
Shift of
0.175mm
(35ppm) /
0.225mm
(45ppm) for
set value 1.
0.175mm
(35ppm) /
0.225mm
(45ppm) for
set value 1.
2
SIMULATION 50-5
LEAD EDGE ADJUSTMENT. SELECT 0-20, AND PRESS START.
0.TRAY SELECT
LEAD EDGE ADJUSTMENT. SELECT 0-20, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
(ADJUSTMENT DATA)
LEAD EDGE: 2.RRCB
LEAD EDGE: 2.RRCB
50
3.SIDE2 ADJ.
50
RESIST: 4.T1
50
5.T2
50
6.DESK
50
7.BPT
50
8.ADU
50
OFF CENTER: 9.T1
50
10.T2
50
11.T3
50
12.T4
50
13.BPT
50
14.ADU
50
(VOID SETTING) 15.LEAD_EDGE(DENA)
50
16.TRAIL_EDGE(DENB)
30
17.FRONT/REAR
30