AR-FX4. Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-FX4 Service Manual online

AR-FX4 ADJUSTMENTS - 2
2. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the mar-
ket.
A. Dial test (<FAX mode> SIM 66-13)
(1) Dial pulse transmission test
1) Execute SIM 66-13 in FAX mode.
2) Execute the dial pulse mode according to the instructions on the
LCD display.
3) Select the dial pulse.
4) Set the make time.
5) Select the dial to be transmitted.
Default: 0123456789
#
(After deleting with the clear key, it can be set to any desired
value.)
6) Transmission is started from the line.
(2) DTMF signal transmission level adjustment
1) Execute SIM 66-13 in the FAX mode.
2) Execute the DTMF mode according to the instructions on the LCD
display.
3) Select the signal transmission level.
The signal transmission level is classified into two groups: the high
group, and the low group.
Transmission can be made with either of default and the soft SW
set value.
4) The transmission level can be set when the following menu is dis-
played on the LCD. (et value 1 = 0.5dB change)
(This value is returned to the original value when the simulation
mode is canceled.)
5) Select the dial signal to be transmitted.
Default: 0123456789
#
(After deleting with the clear key, it can be set to any desired
value.)
6) Start transmission from the line.
SELECT SIGNAL
1:PULSE 2:DTMF
SELECT PULSE
1:10PPS 2:20PPS
INPUT MAKE TIME
(0-15)            _
SEND yyPPS xxm s
1:YES 2:NO
SENDING yyPPS xxm s
SIM
Soft 
SW
Initial 
value
Set value
Dial 
pulse 
make 
time
10 
PPS
FAX 
mode 
66-13
SW 67-
1 – 4
40ms 
(14)
SW set value: 0 – 15
Make time: 26 – 41ms
1ms step 
(Binary 
input)
20 
PPS
SW 67-
5 – 8
0ms
0 fixed
SELECT SIGNAL
1:PULSE 2:DTMF
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            _
H:xx   L:yy
1:YES 2:NO
xx: High group soft SW set value
yy: Low group soft SW set value
SENDING DTMF
SIM
Soft 
SW
Initial 
value
Set value
DTMF 
trans-
mission 
level
High 
group
(FAX 
mode) 66-
13
(Test only)
SW 53-
1 – 4
3.5dB 
(7)
SW set value: 
0 – 15 
Transmission 
level: 0 – 7.5dB
0.5ms 
step 
(Binary 
input)
Low 
group
SW 53-
5 – 8
3.5dB 
(7)
Page of 74
Display

Click on the first or last page to see other AR-FX4 service manuals if exist.