AR-FX4. Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 6

Read Sharp AR-FX4 Service Manual online

AR-FX4 OUTLINE/SPECIFICATIONS - 4
(2) Sender registration
(3) Polling (send request), bulletin board (remote 
transmission) allow number registration)
(4) Letter input
(5) Registered data write
(6) Date/time adjustment
(7) Backup
8. Telephone function system
9. Memory system
10. Additional information function for transmission
11. Additional print function when receiving
Program
Number of items
9 items
Registerable item
All items that can be set in 
transmission, except for time 
setup
Registered name
36 letters
Call method
By pressing program key
Change in setup 
after calling
YES
Sender’s name
36 letters, registered with key operator program
Sender’s number
20 digits, registered with key operator program
Send 
request allow 
number
Registration of 
other party to 
which send 
request is made
10 digits, 20 digits, registered by 
key operator program
System 
number
System number 
registration
Up to 1 number, registered in key 
operator program
ID number
ID number 
registration
Up to 10 items in 4 digits. 
Registered by key operator 
program.
Input method
Key entry
YES
Letters allowed 
for input
Half-size 
characters
Alphabet, Numerical figures, 
Special characters, Codes
YES (Service tool. Dial registration can be made with PC.)
Registered by key operator program.
Backup of registration in power 
failure
SRAM used, by built-in battery
Handset
NO
On-hook function
YES
Reserve
NO
Pause
YES (1 to 15sec: Default 2sec, set 
by key operator program)
Telephone transmission in 
power failure
No (However, external telephone 
transmission is allowed.)
Sound 
volume 
adjustment
Call sound 
volume
YES (Set by key operator program to 
Large/Medium/Small/No sound.)
Line monitor 
sound
YES (Set by key operator program to 
Large/Medium/Small/No sound.)
On-hook sound
YES (Set by key operator program to 
Large/Medium/Small.)
Scan end 
sound
YES (Set by soft switch to Large/
Medium/Small/No sound.)
Communication 
end sound
YES (Set by soft switch to Large/
Medium/Small/No sound.)
Tone pulse switch
Cancel tone/pulse switch setup with 
the key operator program, and set 
with the service switch.
External telephone 
connection
YES
Remote 
reception 
switch
YES (Switch number is in 1 digit + 
∗∗
5
∗∗
Memory capacity
Standard
2MB
Option
Up to 8MB (+2MB/+4MB/+8MB)
Memory content 
(transmission 
reservation) 
confirmation
LCD display
YES
Printout
YES
Memory use status
YES (% display)
Document data memory backup 
in power failure
YES (Flash memory)
Page counter
YES
Date printing
YES (Year/month/day, Year 
in 4 digits)
Date/ display 
sequential switch
NO
Cover paper 
function
Cover 
paper 
item
Date
YES
Receiver’s 
name
YES
Receiver’s 
number
YES
Sender’s 
name
YES
Sender’s 
number
YES
Display of 
number of 
documents 
transmitted
YES
Transmission 
message
YES
Print paper 
size
A4 (AB series)
8.5 x 11 (Inch series)
Transmission 
message
Regular message
CONFIDENTIAL/PLS.
DISTRIBUTE/URGENT/
PLS.
CALL BACK/IMPORTANT
User message
NO
Sender print 
function
Sender’s number
20 digits, registered with 
key operator program
Sender’s name
36 letters
Index print
YES (Set by key operator program)