AR-FX13. Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 52

Read Sharp AR-FX13 Service Manual online

AR-FX13  FAX SOFT SWITCH  5 - 31
SW75 No.5–No.8 Print effective image area main scan 
void
Used to set void amount in print image area.
The void amount in the main scan direction can be adjusted. When
the set value is increased, the margins on the right and the left are
increased.
Setting is made in binary input in the increment of 16 dots.
Default: 48 dots
SW76 No.1 Scan magnification ratio adjustment 
(main scan) flag
Used to set the main scan magnification ratio in scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW76 No.2–No.8 Scan magnification ratio adjustment 
(RSPF main scan)
Used to set the main scan magnification ratio in RSPF scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW77 No.1 Scan magnification ratio adjustment 
(sub scan) flag
Used to set the sub scan magnification ratio in scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW77 No.2–No.8 Scan magnification ratio adjustment 
(RSPF sub scan)
Used to set the sub scan magnification ratio in RSPF scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW78 No.1 Print magnification ratio adjustment 
(main scan) flag
Used to set the main scan magnification ratio in print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW78 No.2–No.8 Print magnification ratio adjustment 
(main scan)
Used to set the main scan magnification ratio in print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW79 No.1 Print magnification ratio adjustment 
(sub scan) flag
Used to set the sub scan magnification ratio in print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW79 No.2–No.8 Print magnification ratio adjustment 
(sub scan)
Used to set the sub scan magnification ratio in print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW80 No.1–No.8 Destination information
Used to set country code.
SW81 No.1–No.8 Language information
Used to set language.
SW82 No.1–No.4 OC scan size default setting
Used to set OC scan default size.
SW82 No.5–No.8 Inhibited to use
SW83 No.1, No.2 Inhibited to use
SW83 No.3–No.8 Speaker sound volume setting pattern 
number
Used to set sound volume pattern of communication end and scan
end.
Default: 1
SW84 No.1–No.8 Inhibited to use
SW85 No.1–No.8 Inhibited to use
SW86 No.1–No.8 Inhibited to use
SW87 No.1–No.8 Inhibited to use
SW88 No.1–No.8 Inhibited to use
SW89 No.1–No.8 Inhibited to use
SW90 No.1–No.8 Inhibited to use
SW91 No.1 Symbol speed 3429 send enable in V.34 send
Used to set whether symbol speed of 3429Hz is allowed or not in
V.34 send.
Default: 1 (Enable)
SW91 No.2 Symbol speed 3200 high carrier send enable 
in V.34 send
Used to set whether use of high carrier is allowed or not when sym-
bol speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.3 Symbol speed 3200 low carrier send enable 
in V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.4 Symbol speed 3000 high carrier send enable 
in V.34 send
Used to set whether use of high carrier is allowed or not when sym-
bol speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.5 Symbol speed 3000 low carrier send enable 
in V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.6 Symbol speed 3429 enable in V.34 
communicate
Used to set whether use of 3429Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
SW91 No.7 Symbol speed 2800 enable in V.34 
communicate
Used to set whether use of 2800Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
Default: 0 0 0 1 (LETTER) (North America) / 
0 0 1 1 (A4) (Other than North America)
Page of 72
Display