Read Sharp AR-FX13 Service Manual online
AR-FX13 FAX SOFT SWITCH 5 - 29
SW51 No.7, No.8 Busy tone detection cycle
Used to set detection cycle of pulses of busy tone for detection of
busy tone.
busy tone.
Default: 0 0 (2puls)
SW52 No.1, No.2 Busy tone detection level
Used to set the mini. Detection level in busy tone detection.
Default: 0 0 (–43dB)
SW52 No.3 Inhibited to use
SW52 No.4 Super G3 disabled in the last call-out of
recall in case of an error
recall in case of an error
Used to set whether Super G3 is disabled or not in the last call-out of
recall in case of a send error.
recall in case of a send error.
When, however, the number of recall in case of a send error is 0, this
function does not operate.
function does not operate.
Default: 0 (Super G3 disabled)
SW52 No.5 Error process in RTN reception
Used to set whether RTN reception is judged as an error or not.
(Only in G3 mode)
(Only in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
Default: 0 (Error)
SW52 No.6, No.7 Inhibited to use
SW52 No.8 V.34 control channel communication speed
Used to set control channel communication speed in V.34 mode.
If the remote machine does not make 2400bps enable, the speed is
always 1200bps.
always 1200bps.
Default: 0 (1200bps)
SW53 No.1–No.4 Maximum DTMF send level
Used to set the max. send level of DTMF signal.
Setting is made in binary input in the increment of 1.0dBm.
Default: 0dBm
SW53 No.5–No.8 DTMF send level (difference between
high and low level)
high and low level)
Used to set DTMF signal send level in low group by the difference
from that in high group.
from that in high group.
Setting is made in binary input in the increment of 0.5dBm.
SW54 No.1–No.4 Scan effective image area sub scan
lead edge image loss (RSPF)
lead edge image loss (RSPF)
Used to set image loss in scan image area.
Image loss on the lead edge in RSPF sub scan direction can be
adjusted. When the set value is increased, image loss on the lead
edge is increased.
adjusted. When the set value is increased, image loss on the lead
edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW54 No.5–No.8 Scan effective image area sub scan
rear edge image loss (RSPF)
rear edge image loss (RSPF)
Used to set image loss in scan image area.
Image loss on the rear edge in RSPF sub scan direction can be
adjusted. When the set value is increased, image loss on the rear
edge is increased.
adjusted. When the set value is increased, image loss on the rear
edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW55 No.1–No.7 CI signal OFF detection enable time
Used to set the min. OFF time for judgment of 1 pulse (1 call) of CI
(call-in signal).
(call-in signal).
If OFF time continues more than the set value, it is judged as 1
pulse.
pulse.
Setting is made in binary input in the increment of 10ms.
Default: 1200ms (Other than New Zealand) / 1100ms (New Zealand)
SW55 No.8 Inhibited to use
SW56 No.1–No.3 CI signal ON detection enable time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI
(call-in signal).
(call-in signal).
If ON time continues more than the set value, it is judged as 1 pulse.
Setting is made in binary input in the increment of 10ms.
SW56 No.4 Inhibited to use
SW56 No.5, No.6 DT/BT detection frequency range
Used to set DT/BT detection frequency range.
SW56 No.7, No.8 Inhibited to use
SW57 No.1 Inhibited to use
SW57 No.2 Sharp machine mode
Used to set whether communication is made in Sharp machine
mode or not.
mode or not.
Default: 1 (ON)
SW57 No.3 Inhibited to use
SW57 No.4–No.8 Reception gain adjustment
Used to set reception gain correction.
Setting is made in binary input in the increment of 0.5dBm.
Default: 0.0dBm
SW58 No.1–No.4 Dual wait inhibit time after CFR send
Used to set dual wait inhibit time after CFR send.
Setting is made in binary input in the increment of 200ms.
Default: 1600ms
SW58 No.5–No.8 FSK signal settlement time in double
wait
wait
Used to set FSK signal settlement time in double (dual) wait.
Setting is made in binary input in the increment of 50ms.
Default: 550ms (7)
SW59 No.1, No.2 Inhibited to use
SW59 No.3, No.4 Reception SED ON level
Used to set reception SED ON level.
Default: 1 1 (–48dB)
SW59 No.5, No.6 Transmission cable amplitude
equalizer
equalizer
Used to set transmission cable amplitude equalizer.
SW59 No.7, No.8 Reception cable amplitude equalizer
Used to set reception cable amplitude equalizer.
Default: 0 0 (0dB)
Default: +2.0dBm (Other than New Zealand) /
+1.5dBm (New Zealand)
Default: 155ms (North America, Europe) /
195ms (Australia, New Zealand)
Default: 1 1 (245Hz–650Hz) (Other than New Zealand) /
1 0 (360Hz–440Hz) (New Zealand)
Default: 0 0 (0dB) (North America, Europe) /
0 1 (4dB) (Australia, New Zealand)