AR-FX13. Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 20

Read Sharp AR-FX13 Service Manual online

AR-FX13  SIMULATION  4 - 10
66
33
Signal detection check
[Function]
Use to check the signal detection.
[Operation]
34
Communication time 
measurement
[Function]
Use to measurement the communication time.
[Operation]
37
Speaker sound 
volume setting
[Function]
Use to set the speaker sound volume.
1: NO SOUND
2: LOW
3: MID
4: HIGH
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
When a signal is detected, the display is changed from NONE to the following.
CI/CNG/CED/BT/DT/Flag/SDT/DTMF
∗ [Clear] key: Returns to the main-sub code input display.
CHECKING        NONE
PRESS CLEAR TO STOP
1) Initial display
"xx:xx:xx:xxx" indicates o'clock, minute, second, millisecond.
∗ [Clear] key: Returns to the main-sub code input display.
COMM. TIME
xx:xx:xx:xxx msec
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
→ 2 → 3
→ 4 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: Returns to the main-sub code input display.
3) [ENTER]/[OK] key
xxx: Set content
After 2sec, main code and sub code input display.
SELECT SPEEKER VOL.
PRESS 
SELECT (1-4)
1:NO SOUND
SELECT (1-4)
2:LOW
.....
STORED
xxx
Page of 72