SW
No.
No.
Bit
No.
ITEM
Soft SW setting and function
Factory Setting
11
1
Header
Used to set the header attachment to the transmitting
document.
document.
0
2
Header in data transfer
Used to set the header attachment to the transferring
document.
document.
0
3
Training (EQM) threshold value
Used to select the threshold value to judge Success/Failure
of training in reception of training.
of training in reception of training.
0
4
Reserved
0
5
6
7
6
7
Non ECM error judgement
threshold value
threshold value
0
1
0
1
0
8
Reserved
0
12
1
2
3
4
5
2
3
4
5
Activity Report Auto Listing time
Used to set the start time of Activity Report.
Setup is made in the unit of one hour, and setup of minutes
cannot be made.
Setup is made in the unit of one hour, and setup of minutes
cannot be made.
Print start time =
Bit1
Bit1
× 16 + Bit2 × 8 + Bit3 × 4 + Bit4 × 2 + Bit5 hour 00 min
Set range = 0
∼ 23
Factory Setting = 00:00
0
0
0
0
0
0
0
0
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
13
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
14
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
15
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
1 : Not attached
0 : Attached
1 : Not attached
0 : Attached
1 : Easy to fall back
0 : Normal
Bit 5, 6, 7
RTP
RTN
000
32
64
001
16
32
010
12
24
011
8
16
100
6
12
101
4
8
AR-F151