Read Sharp AR-F151 (serv.man11) Service Manual online
SW
No.
No.
Bit
No.
ITEM
Soft SW setting and function
Factory Setting
8
5
EOL detection timer
Used to set the EOL (End of Life) detection time to 25sec or
13sec. This function is effective to avoid a communication
error due to long EOL of certain models.
13sec. This function is effective to avoid a communication
error due to long EOL of certain models.
0
6
Reserved
0
7
Reserved
0
8
ECM
Used to set ON/OFF of ECM.
1
9
1
2
2
Interval between OFF-HOOK and
dial send
dial send
Used to set the delay from OFF-HOOK when starting dialing
to actual send start of the dial signal.
If the dial tone detection function is enabled, this setup is
ignored.
to actual send start of the dial signal.
If the dial tone detection function is enabled, this setup is
ignored.
1
1
1
3
Reserved
0
4
Reserved
0
5
6
6
Reserved
0
0
0
7
8
8
Reserved
0
0
0
10
1
Reserved
0
2
FAST
Used to set Enable/Disable of RMS (FAST) function.
0
3
Reserved
1
4
Basic resolution
Used to select the basic resolution for scanning and printing.
0
5
Reserved
0
6
7
8
7
8
Language
Used to select the language displayed on the LCD and the
report. The correspondence between language N and the
actual language differs depending on the destination.
report. The correspondence between language N and the
actual language differs depending on the destination.
0
0
0
0
0
1 : 25 sec
0 : 5 sec
1 : ON
0 : OFF
Bit No.
0.5sec
1sec
2sec
3sec
1
0
0
1
1
2
0
1
0
1
1 : Enable
0 : Disable
1 : Inch series
0 : Metric series
Language 1
Language 2
Language 3
For North
America
American
English
French
Spanish
Bit
No.
Lan-
guage
1
Lan-
guage
2
Lan-
guage
3
Reserved
6
0
0
0
0
1
1
1
1
7
0
0
1
1
0
0
1
1
8
0
1
0
1
0
1
0
1
AR-F151
9 – 23