AR-F14 (serv.man9). 9. Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 2

Read Sharp AR-F14 (serv.man9) Service Manual online

AR-F14/PN1 TROUBLE SHOOTING 9-2
3. Troubleshooting
A. Finisher/saddle unit
(1) F1-03, Paddle Motor Fault (detail code: 01/02/03/04)
(2) F1-10, Staple/fold Motor Fault
F1
34
Content
Console finisher (AR-F14) 
punch (AR-PN1) motor trouble
Detail
Punch motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
35
Content
Console finisher (AR-F14) 
punch (AR-PN1) side registration sensor 
trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
Harness disconnection
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-2) to check the sensor 
operation.
36
Content
Console finisher (AR-F14) 
punch (AR-PN1) timing sensor trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
Harness disconnection
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-2) to check the sensor 
operation.
37
Content
Console finisher (AR-F14) 
backup RAM trouble
Detail
Backup RAM contents are disturbed.
Cause
Console finisher control PWB trouble
Malfunction by noise
Check and 
remedy
Replace the console finisher control PWB.
F1
38
Content
Console finisher (AR-F14) 
punch (AR-PN1) backup RAM trouble
Detail
Punch unit backup RAM contents are 
disturbed.
Cause
Punch control PWB trouble
Malfunction by noise
Check and 
remedy
Replace the punch control PWB.
39
Content
Console finisher (AR-F14)Punch sensor 
trouble (AR-PN1)
Detail
Sensor input abnormality
Cause
Sensor breakage harness disconnection 
console finisher control PWB defect 
Check and 
Remedy
Sensor operation check in diag (SIM 3-2)
40
Content
Console finisher (AR-F14)Puncher section 
power trouble (AR-PN1)
Detail
Puncher operation abnormality
Cause
Punch control PWB defect
Check and 
Remedy
Punch control PWB replacement 
53
Content
Console finisher (AR-F14)Interface transport 
unit connection trouble
Detail
Connection error between console finisher 
and interface transport unit 
Cause
Improper connection of connector between 
console finisher and interface transport unit
Check and 
Remedy
Check the interface transport unit connector. 
81
Content
Console finisher transport motor abnormality
Detail
Transport motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
Cause/Trouble section
Procedure
Check
Result
Remedy
Paddle home position sensor (PHPS)
1
Check the paddle home position sensor. Is the sensor normal?
NO
Replace the sensor
Swing guide home position sensor 
(ARHPS)
2
Check the swing guide home position sensor.  
Is the sensor normal?
NO
Replace the sensor.
Wiring
3
Is the wiring between the finisher controller PCB and the paddle 
motor normal?
NO
Correct the wiring.
Paddle, Swing guide assembly
4
Try turning the paddle motor clockwise and counterclockwise by 
hands.  Is there mechanical tapping in the rotation of the paddle 
or the up/down movement of the swing guide?
YES
Correct the 
mechanical 
mechanism.
Paddle motor (FPM), 
finisher controller PCB
5
Try replacing the paddle motor. Is the problem corrected?
YES
End.
NO
Replace the finisher 
controller PCB.
Cause/Trouble section
Procedure
Check
Result
Remedy
Wiring
1
Is the wiring between the finisher controller PCB and the staple/
fold motor normal?
NO
Correct the wiring.
Stapler unit
2
Try turning the staple jam releasing dial. 
Is there mechanical trapping?
YES
Correct the 
mechanical system.
Staple/fold motor (FFSM), 
Finisher controller PCB
3
Try replacing the staple/fold motor. Is the problem corrected?
YES
End.
NO
Replace the finisher 
controller PCB.