AR-C330  SETTING AND ADJUSTMENTS  7 - 31
Troubleshooting on copy color balance and density
If the copy quality adjustment cannot provide a normal copy quality, check the following items.
Check that the following simulation values are in the specified range. If any value is improper, check the machine conditions and replace
consumable parts or take necessary measures.
Perform the following procedures.
Check that the following simulation values are in the specified range. If not, troubleshoot the cause and repair.
SIM No
ITEM
SPEC
NOTE
GR
BS
DV
BS
Standard value
Fixed
Standard value
Fixed
44-9
(NORMAL 
MODE) 
(2/6)
BLACK
333 to 900
545
150 – 700
325
A greater difference between GR-BS(XXX) and 
DV-BS(XXX) means a greater correction quantity 
of the DV bias voltage and of the main charger grid 
voltage. It may be judged that the image process 
section conditions are degraded. (The deterioration 
degree of developer, the OPC drum, the transfer 
belt, the transfer roller, and the main charger, etc. 
may be presumed.)
CYAN
305 to 900
555
125 to 700
MAGENTA
YELLOW
JOB No
WORK ITEM
SIM No
Trouble caused by improper 
adjustment
NOTE
ADJ M4 High 
voltage 
adjustment
ADJ 1
Main 
charger 
grid voltage 
adjustment
8-2
Improper image density 
(especially in the high density 
section), improper copy, image 
density section copy abnormality, 
chip on the edge of half-tone 
images
If the digital 
multi-meter 
and the high 
voltage 
probe 
specified on 
the Service 
Manual are 
not available, 
set the 
adjustment 
value to the 
default.
Check and adjust when the high 
voltage PWB (Main charger / DV 
bias) is replaced. / Adjust when 
the output is not in the specified 
level. / Check and adjust when the 
copy/print quality (density, color 
balance) adjustment does not 
provide a satisfactory result.
ADJ 2
DV bias 
voltage 
adjustment
8-1
Improper image density, improper 
copy, image density section copy 
abnormality, chip on the edge of 
half-tone images
Check and adjust when the high 
voltage PWB (Main charger / DV 
bias) is replaced. / Adjust when 
the output is not in the specified 
level. / Check and adjust when the 
copy/print quality (density, color 
balance) adjustment does not 
provide a satisfactory result.
ADJ 3
Transfer 
voltage 
adjustment
44-30 
Improper image density, half-tone 
image section improper copy, high 
density image section density 
unevenness and improper copy, 
low density inside image outline
Check and adjust when the high 
voltage PWB (Transfer) is 
replaced. / Adjust when the output 
is not in the specified level. / 
Check and adjust when the copy/
print quality (density, color 
balance) adjustment does not 
provide a satisfactory result.
ADJ M6 Image 
density 
sensor 
adjustment
ADJ 1
Image 
density 
sensor 
calibration
44-13
Because of improper operation of 
the process correction (high 
density section image density 
correction), parameters of the 
voltage,  the current, and the laser 
power of the process section 
become improper to cause 
improper image density, improper 
copy, abnormal copy, chip on the 
edge of half-tone image, tone gap, 
improper color balance, etc. / Error 
F2-44 – 45, 80 – 90
Adjust when the copy/print quality 
(density, color balance) 
adjustment does not provide a 
satisfactory result or when an 
error F2-44 – 45, 80 – 90 occurs.
ADJ 2
Image 
density 
sensor 
position 
adjustment
44-23
SIM No
ITEM
Display value at 25°C, 
70% (Reference value)
Phenomenon when the sensor operation is abnormal
NOTE
44-14
TEMPERATURE 100 to 120
The process section 
correction for change in 
temperature/humidity is 
not performed. (Toner 
density, transfer voltage, 
resist roller RPM 
corrections)
(Improper color balance, 
abnormal copy, improper 
copy, toner dispersion, 
improper image density, 
image deflection, image dirt, 
decreased density inside 
image outline)
Check the relationship 
between the actual 
environment and the 
sensor output level, and 
check that the sensor is 
operating properly.
HUMIDITY
35 to 45