AR-C270 (serv.man51). Introduction of AR-DW1N New Type Developer - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp AR-C270 (serv.man51) Technical Bulletin online

 
 
GMA051202 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
 
Firmware Revision 
 
 
AR-C150 
 
 
AR-C160 
 
 
AR-C250 
 
 
AR-C270 
 
Current 
New 
 
Current 
New 
 
Current 
New 
 
Current 
ICU 
6.01 
6.01 
 
3.05 
3.06 
 
4.02 
4.02 
 
3.00 
PCU 
6.02a 
6.02c 
 
3.06 
3.08 
 
4.03 
4.05 
 
3.02 
PCU Sub 
5.05 
5.05 
 
3.01 
3.01 
 
3.01 
3.01 
 
3.01 
OPE 
6.00 
6.00 
 
3.01 
3.03 
 
4.01 
4.01 
 
3.00 
 
Please note that the enhancements are effective, only when new Developer, Developer Units 
and Engine Firmware have been installed/upgraded.
 
 
If the wrong combination is used (old type DV unit and new type Developer), it will not be 
effective and will cause copy quality problems (DV particles will attach to the drum). 
 
Please refer to the following Compatibility Table:- 
 
 
 
Current Developer 
New Developer 
Condition 
Black 
Colour 
Black 
Colour 
 
 
AR-C15LD1 
AR-C16LD1 
AR-C15LD9 
AR-C18LD1 
AR-C17LD9 
 
Current Firmware &  
AR-C150 
AR-C250 
ü
 
X
 
ü
 
X
 
X
 
AR-DW1 installed 
 
AR-C160 
X
 
ü
 
ü
 
X
 
X
 
 
Upgraded 
Firmware  
AR-C150 
AR-C250 
ü
 
X
 
ü
 
X
 
X
 
AR-DW1
 installed 
AR-C160 
 
X
 
ü
 
ü
 
X
 
X
 
 
Upgraded 
Firmware  
AR-C150 
AR-C250 
NG
 
X
 
NG
 
ü
 
ü
 
AR-DW1N
 
installed 
AR-C160 
AR-C270 
X
 
NG
 
X
 
ü
 
ü
 
 
ü 
Compatible and OK to Install. 
NG
 
Toner spatter/dusting may be experienced (not recommended). 
X
 
Not compatible – DO NOT USE OR INSTALL. 
 
All existing AR-C150, AR-C160 & AR-C250 models can be modified to the same image quality level as the new 
AR-C270 by installing new type Developer Units, Developer and Engine Firmware.  
 
Please refer to the following installation procedure:- 
 
Installation Procedure 
 
1. 
Enter Test Simulations 8 –01 and 8-02 and confirm that both DV Bias and Main Charge Grid Bias 
output voltages are set to their default values, as shown below.  
 
 
 
 
Developing Bias Voltage – Sim 8-01 (All Models) 
 
Colour 
Sim 8-01  Adjustment Value 
325 
325 
325 
325 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 
Page of 5
Display

Click on the first or last page to see other AR-C270 (serv.man51) service manuals if exist.