AR-C270 (serv.man15). (Section 11) Maintenance Disassembly Assembly - Sharp Copying Equipment Service Manual (repair manual). Page 32

Read Sharp AR-C270 (serv.man15) Service Manual online

3) Remove the parts, and remove the paper exit roller
(S07/Ua02/P02/CLN).
Clean with alcohol.
Apply grease to the gear (S07/Ua02/P03/GRE) and the inside
of the paper exit idle roller (S07/Ua02/P04/CLN/GRE).
S10
PWB
 S10/P01 
ICU main PWB
 S10/P02 
ICU image PWB
 S10/P03 
ICU scan PWB
(AR-C150/C250)
1)
Remove the original cover.  S01/P01 
2)
Remove the rear cover upper.  S01/P02 
3)
Remove the glass holder right.  S01/P05 
4)
Remove the glass holder left.  S01/P06 
5)
Remove the table glass.  S01/P07 
6)
Remove the shading glass AS.  S01/P08 
7)
Remove the operation unit.  S02/Ua01 
8)
Remove the screw, and remove the dark box cover.
9)
Remove the screw, and remove the flat cable holder.
10) Remove the flat cable from the CCD.
11) Remove the screw, and remove the scanner fixing angle.
12) Remove the screw, and remove the stopper.
13) Open the scanner (reading) unit. Support it with the stopper.
14) Remove the screw, and remove the ICU cover.
15) Remove the ICU main PWB, the ICU image PWB, and the ICU
scan PWB.
S07/Ua02/P02/CLN
S07/Ua02/P04/CLN/GRE
S07/Ua02/P03/GRE
S04/Ua01
11 –  32
Page of 36