AR-C270 (serv.man13). (Section 8) Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 12

Read Sharp AR-C270 (serv.man13) Service Manual online

Model
Main 
code
Sub
code
Content
AR-C100, 
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
F2
80
Half tone process control 1st batch
trouble (Black)
81
Half tone process control 1st batch
trouble (Cyan)
82
Half tone process control 1st batch
trouble (Magenta)
83
Half tone process control 1st batch
trouble (Yellow)
84
Half tone process control 2nd batch
trouble (Black)
85
Half tone process control 2nd batch
trouble (Cyan)
86
Half tone process control 2nd batch
trouble (Magenta)
87
Half tone process control 2nd batch
trouble (Yellow)
90
Half tone process control error
F3
12
Cassette 1 lift up trouble
22
Cassette 2 lift up trouble
32
Cassette 3 lift up trouble
42
Cassette 4 lift up trouble
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
F9
00
ICU-PRT communication trouble (ICU
detection)
AR-C100, 
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
H2
00
Thermistor open/Fusing unit not installed
(HL1)
01
Thermistor open/Fusing unit not installed
(HL2)
02
Thermistor open/Fusing unit not installed
(HL3)
AR-C100, 
AR-C150, 
AR-C250
H2
03
Thermistor open/Fusing unit not installed
(HL4)
The thermistor is open. (The input
voltage of 4.6V or more is detected.) The
fusing unit is not installed.
H3
00
Fusing section high temperature trouble
(HL1)
01
Fusing section high temperature trouble
(HL2)
02
Fusing section high temperature trouble
(HL3)
03
Fusing section high temperature trouble
(HL4) The fusing temperature exceeds
220 C. (The input voltage of 0.85V or
less is detected.) Thermitor trouble,
control PWB trouble, fusing section
connector trouble, AC power trouble 
H4
00
Fusing section low temperature trouble
(HL1)
01
Fusing section low temperature trouble
(HL2)
H5
01
3-time continuous detection of
POD/DPID not-reaching jam
H6
00
Fusing oil remaining quantity abnormality
detection
H7
00
AC input voltage (HLV) abnormality
detection
AR-C100, 
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
L1
00
Mirror feed trouble
L3
00
Mirror return trouble
L4
03
Fusing motor trouble
04
Developing motor trouble (Black)
05
Developing motor trouble (Color)
06
Transfer belt lift motor trouble
Model
Main 
code
Sub
code
Content
AR-C100, 
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
L6
10
Polygon motor lock detection (Black)
11
Polygon motor lock detection (Cyan)
12
Polygon motor lock detection (Magenta)
13
Polygon motor lock detection (Yellow)
L8
01
No full wave signal
02
Full wave signal abnormality
PF
00
RIC copy inhibition signal reception
U0
00
OPE-PCU sub communication trouble
(OPE/PCU detection)
80
PCU-PCU sub communication trouble
(PCU detection)
U2
00
EEPROM read/write error (PCU
detection)
11
Counter check sum error(PCU)
12
Adjustment value check sum error (PCU)
20
EEPROM read/write error (ICU)
21
Counter check sum error (ICU)
22
Adjustment value check sum error (ICU)
30
Manufacturing No. data discrepancy
U4
00
ADU communication trouble
02
ADU alignment plate operation
abnormality
12
ADU transport motor trouble
U5
00
ADF communication trouble
01
ADF resist sensor error
02
ADF repulsion sensor error
03
ADF timing sensor error
11
Paper fed motor operation trouble
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
U6
09
LCC lift motor trouble
20
LCC communication trouble
21
LCC transport motor trouble
22
LCC 24V power abnormality
AR-C100, 
AR-C150, 
AR-C250, 
AR-C160, 
AR-C270
U7
00
RIC communication trouble
UC
00
CPT board communication trouble
01
CPT board program hung up
02
CPT board ASIC abnormality
03
CPT board ROM abnormality
04
CPT board RAM abnormality
05
CPT board model code abnormality
22 - 10
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the system configuration (option, internal
hardware). (AR-C150/C250/C160/C270)
Item
Specifications
Options
Operation/
Procedure
This simulation allows to check the system configura-
tion.
The devices and the option units which are installed are
displayed with the model names, etc.
8 –  12
Page of 34
Display