GENERAL PROGRAMS
Device control
Use these programs when a peripheral device on the
machine has failed or when you wish to temporarily
disable a device. The programs can also be used to
change the function setting of a device as required by
your conditions of use.
"Device control" consists of the following programs:
●Original size detector setting
●Disabling of document feeder
●Disabling of duplex
●Disabling of inverter
●Disabling of stapler
●Disabling of optional paper drawer
●Disabling of large capacity cassette
●Disabling of shifter
●Disabling of finisher
●Saddle stitch position adjust
●Stream feeding mode
●Auto paper selection setting
●Registration adjustment
●Return from copy mode timing
Original size detector setting
This program is used to select the standard original
sizes that can be detected by the original size detection
function. Select one of the four groups indicated below.
The factory default setting is "AB-1 (INCH-1)". Original
size detection by the document glass can also be
disabled (CANCEL DETECTION AT DOCUMENT
GLASS).
If "CANCEL DETECTION AT DOCUMENT GLASS" is
set, originals will be regarded as EXTRA for all copier
functions and no original size will be displayed.
Disabling of document feeder
This program is used to prevent use of the reversing
automatic document feeder when it malfunctions. In
this case, scanning can still be performed using the
document glass.
Disabling of duplex
This program is used to disable duplex printing when
the duplex module malfunctions. If this program is set,
only one-sided printing can be performed.
Disabling of inverter
Use this program when you need to prohibit the
inverter function or when the duplex bypass/inverter
unit has failed. When the program is turned on, pages
are only output face-down to the centre tray of the
machine. Duplex printing is also not possible (only one-
sided printing is possible).
Disabling of stapler
This program is used to disable stapling when the
stapler unit of the saddle stitch finisher malfunctions.
Disabling of optional paper drawer
This program is used to disable use of the stand/1 x
500 sheet paper drawer, stand/3 x 500 sheet paper
drawer or duplex module/2 x 500 sheet paper drawer
when it malfunctions.
Disabling of large capacity cassette
Use this program when you wish to prohibit use of the
large capacity cassette or when it has failed.
Disabling of shifter
Use this program when you need to prohibit the shifter
function in the centre tray or when the shifter has failed.
When the program is turned on, the offset feature that
offsets sets of copies or printed pages in the centre tray
will not function.
Disabling of finisher
This program is used to disable use of the saddle stitch
finisher when it malfunctions.
Group
Detectable original sizes
Document feeder tray (for reversing
automatic document feeding)
Document glass
1 INCH - 1
11" x 17", 8-1/2" x 14",
8-1/2" x 11", 
8-1/2" x 11"R,
5-1/2" x 8-1/2"
A3, B4, A4,
B5, B5R
2 INCH - 2
11" x 17", 8-1/2" x 13",
8-1/2" x 11", 
8-1/2" x 11"R,
5-1/2" x 8-1/2"
A3, B4, A4,
B5, B5R
3 AB - 1
A3, A4, A4R, A5,
B4, B5, B5R
11" x 17", 8-1/2" x 14",
8-1/2" x 11"
4 AB - 2
A3, A4, A4R, A5,
B5, B5R, 8-1/2" x 13"
11" x 17", 8-1/2" x 11",
B4
NOTE
If the duplex module/2 x 500 sheet paper drawer is
disabled, automatic two-sided printing cannot be
performed.