AR-C260 (serv.man14). (11) Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 22

Read Sharp AR-C260 (serv.man14) Service Manual online

AR-C260/C260M  TROUBLESHOOTING  11 - 22
Main 
code
Sub 
code
Title
ICU-OPE communication trouble 
(ICU/OPE detection)
U0
00
Display
Lamp/Message
Phenomenon
Detail
Communication 
establishment error, 
framing/parity/protocol 
error
Section
Case 1
Cause
Disconnection of the 
operation panel 
communication connector 
of the ICU/MFP PWB, 
harness trouble between 
the ICU PWB and the MFP 
PWB.
Check & 
Remedy
Check the connector and 
the harness between the 
ICU PWB and the MFP 
PWB.
Case 2
Cause
ICU/MFP PWB trouble
Check & 
Remedy
Check grounding of the 
machine.
Replace the ICU PWB or 
the MFP PWB. 
Main 
code
Sub 
code
Title
RTC read trouble
U1
02
Display
Lamp/Message
Phenomenon
Detail
Abnormal value is read 
from the RTC on the ICU 
PWB. 
Section
Case 1
Cause
RTC circuit abnormality
Check & 
Remedy
Set the time again with the 
key operation, and check 
that time advances 
properly.
Check the RTC circuit. 
Main 
code
Sub 
code
Title
EEPROM read/write error (ICU 
detection)
U2
00
Display
Lamp/Message
Phenomenon
Detail
EEPROM version error
EEPROM write error
Section
Case 1
Cause
EEPROM trouble. 
EEPROM is not initialized. 
Check & 
Remedy
1. Check that the 
EEPROM is properly 
set.
2. Use SIM 16 to cancel 
the error. 
Case 2
Cause
ICU PWB EEPROM 
access circuit trouble
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the 
adjustment data, 
record them with the 
simulation. (When a 
printer option is 
installed, use SIM 22-1 
to record the counter 
data and the 
adjustment data.)
2. Replace the ICU PWB.
3. Use SIM 16 to cancel 
the error.
Main 
code
Sub 
code
Title
EEPROM check sum error (ICU 
detection)
U2
11
Display
Lamp/Message
Phenomenon
Detail
EEPROM (ICU) check 
sum error
Section
Case 1
Cause
EEPROM trouble
Check & 
Remedy
1. Check that the 
EEPROM is properly 
set.
2. Use SIM 16 to cancel 
the error.
Case 2
Cause
Control circuit freeze by 
noises.
ICU PWB EEPROM 
access circuit trouble.
Check & 
Remedy
1. To prevent against 
deletion of the counter 
data and the 
adjustment data, 
record them with the 
simulation. (When a 
printer option is 
installed, use SIM 22-1 
to record the counter 
data and the 
adjustment data.)
2. Replace the ICU PWB.
3. Use SIM 16 to cancel 
the error.
Main 
code
Sub 
code
Title
Production No. data discrepancy 
U2
30
Display
Lamp/Message
Phenomenon
Detail
The production No. 
recorded in the PCU 
differs from that recorded 
in the ICU. 
Section
Case 1
Cause
EEPROM is not 
exchanged when replacing 
the PCU/ICU PWB. 
Check & 
Remedy
Check that the EEPROM 
is properly installed. When 
replacement, check that 
the EEPROM before 
replacement is inserted to 
the board after 
replacement. 
Page of 25