AR-C260 (serv.man14). (11) Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 20

Read Sharp AR-C260 (serv.man14) Service Manual online

AR-C260/C260M  TROUBLESHOOTING  11 - 20
Main 
code
Sub 
code
Title
Fusing unit initial detection trouble
H8
01
Display
Lamp/Message
Phenomenon
Detail
Fusing unit initial detection 
trouble
Section
Fusing
Case 1
Cause
Disconnection of the 
connector
Check & 
Remedy
Check connection of the 
fusing unit initial sensor. 
Check connection of the 
connector and the harness 
to the PCU PWB. 
Case 2
Cause
Connector harness trouble
Check & 
Remedy
Check for disconnection of 
the harness. 
Case 3
Cause
Fusing unit trouble
Check & 
Remedy
Replace the fusing unit.
Main 
code
Sub 
code
Title
Mirror feed trouble
L1 
00
Display
Lamp/Message
Phenomenon
Detail
Mirror feed is not 
completed within the 
specified time. 
Section
Case 1
Cause
Mirror unit trouble, mirror 
wire breakage
Check & 
Remedy
Use SIM 1-1 to check the 
mirror operation. 
Main 
code
Sub 
code
Title
Mirror return trouble
L3
00
Display
Lamp/Message
Phenomenon
Detail
Mirror return is not 
completed within the 
specified time. 
Section
Case 1
Cause
Mirror unit trouble, mirror 
wire breakage
Check & 
Remedy
Use SIM 1-1 to check the 
mirror operation. 
Main 
code
Sub 
code
Title
Paper feed motor lock trouble
L4
02
Display
Lamp/Message
Phenomenon
Detail
In warm-up, or in canceling 
a jam, the paper feed 
motor is rotated, and the 
lock signal is not detected 
within 1sec.
Section
Paper feed
Case 1
Cause
Paper feed motor trouble, 
disconnection of the 
harness between the PCU 
PWB and the paper feed 
motor, control circuit 
trouble
Check & 
Remedy
Use SIM 6-1 to check the 
paper feed motor 
operation. Check the 
harness and the connector 
between the PCU PWB 
and the paper feed motor.
Main 
code
Sub 
code
Title
Transfer belt lift motor trouble
L4
06
Display
Lamp/Message
Phenomenon
Detail
When the belt motor lifts 
up or down, the change in 
the belt home position 
sensor characteristics is 
not detected within the 
specified time. 
(When the motor lifts up, 
the lower limit sensor 
remains ON after the 
specified time.)
(When the motor lifts 
down, the lower limit 
sensor does not turn on 
after the specified time.)
Section
Paper feed
Case 1
Cause
Belt lift motor trouble, 
disconnection of the 
harness between the PCU 
PWB and the belt lift motor, 
control circuit trouble
Check & 
Remedy
Use SIM 6-1 to check the 
belt lift motor operation. 
Check the harness and the 
connector between the PCU 
PWB and the belt lift motor. 
Main 
code
Sub 
code
Title
Transfer belt motor trouble
L4
07
Display
Lamp/Message
Phenomenon
Detail
1) Before driving the drum, 
the calibration plate is 
opened with the process 
control BK sensor, and 
light is emitted with the 
gain value of 0 and with 
the light emitting quantity 
fixed to 120. The average 
of ten light quantities 
repeats to be 5 or less for 
3 times continuously.
2) Immediately after 
driving the drum, the 
calibration plate is opened 
with the process control 
BK sensor, and one whole 
turn of the belt surface is 
scanned with the gain 
value of 0 and with the 
light emitting quantity at 
the optimum value (120 ~ 
50). The difference 
between the max. value 
and the min. value of the 
scanned data is 5 or less.
Section
Paper feed
Page of 25
Display