AR-C260 (serv.man14). (11) Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 17

Read Sharp AR-C260 (serv.man14) Service Manual online

AR-C260/C260M  TROUBLESHOOTING  11 - 17
Main 
code
Sub 
code
Title
Half-tone process control 2nd 
batch trouble (Magenta)
F2
86
Display
Lamp/Message
Phenomenon
Detail
Second step operation 
error during half-tone 
process control
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain. 
Case 1
Cause
When "Error" occurs in the 
gain adjustment of SIM 44-
2:
1. Disconnection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Image density sensor 
dirt/trouble
Check & 
Remedy
1. Check connection of 
the harness between 
the PCU PWB and the 
image density sensor.
2. Clean/replace the 
image density sensor. 
Case 2
Cause
When SIM 44-2 gain 
adjustment is completed:
Insufficient cleaning of the 
transfer belt, calibration 
plate solenoid operation 
trouble
Check & 
Remedy
Check the drum surface 
and the belt surface. 
Main 
code
Sub 
code
Title
Half-tone process control 2nd 
batch trouble (Yellow)
F2
87
Display
Lamp/Message
Phenomenon
Detail
Second step operation 
error during half-tone 
process control
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain. 
Case 1
Cause
When "Error" occurs in the 
gain adjustment of SIM 44-
2:
1. Disconnection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Image density sensor 
dirt/trouble
Check & 
Remedy
1. Check connection of 
the harness between 
the PCU PWB and the 
image density sensor.
2. Clean/replace the 
image density sensor. 
Case 2
Cause
When SIM 44-2 gain 
adjustment is completed:
Insufficient cleaning of the 
transfer belt, calibration 
plate solenoid operation 
trouble
Check & 
Remedy
Check the drum surface 
and the belt surface. 
Main 
code
Sub 
code
Title
Half-tone process limit error
F2
90
Display
Lamp/Message
Phenomenon
Detail
The difference between 
the correction value after 
execution of half-tone 
process control and the 
previous correction value 
exceeds the specified 
max. value of each color.
<The error is recorded in 
the trouble history, but F2 
trouble is not indicated on 
the display and the 
previous correction value 
is remained.> 
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain. 
Case 1
Cause
When "Error" occurs in the 
gain adjustment of SIM 44-
2:
1. Disconnection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Image density sensor 
dirt/trouble
Check & 
Remedy
1. Check connection of 
the harness between 
the PCU PWB and the 
image density sensor.
2. Clean/replace the 
image density sensor. 
Case 2
Cause
When SIM 44-2 gain 
adjustment is completed: 
Insufficient cleaning of the 
transfer belt, calibration 
plate solenoid operation 
trouble
Check & 
Remedy
Check the drum surface 
and the belt surface. 
Main 
code
Sub 
code
Title
Cassette 1 lift-up trouble
F3
12
Display
Lamp/Message
Phenomenon
Detail
LUD1 does not turn on 
within the specified time. 
Section
Case 1
Cause
LUD1 sensor trouble, 
disconnection of harness 
among the PCU PWB, the 
lift-up unit, and the paper 
feed unit. 
Check & 
Remedy
Check LUD1, its harness, 
and the connector. 
Case 2
Cause
Cassette 1 lift-up motor 
trouble
Check & 
Remedy
Check the lift-up unit. 
Page of 25
Display

Click on the first or last page to see other AR-C260 (serv.man14) service manuals if exist.