AR-C260/C260M TROUBLESHOOTING 11 - 13
Main
code
code
Sub
code
Title
Toner empty sensor abnormality
(Yellow)
(Yellow)
F2
43
Display
Lamp/Message
Phenomenon
Detail
Toner empty sensor output
abnormality
abnormality
Section
Cartridge
Case 1
Cause
Connector harness
trouble, connector
disconnection
trouble, connector
disconnection
Check &
Remedy
Remedy
1. Check connection of
the toner empty
sensor.
sensor.
→
Connect it
properly.
2. Check connection of
the connector harness
to the PCU PWB.
to the PCU PWB.
→
Connect it properly.
3. Check connection of
the cartridge.
→
Connect it properly.
4. Check for disconnection
of the harness.
→
Replace the harness.
Case 2
Cause
Cartridge trouble
Check &
Remedy
Remedy
Replace the cartridge.
Main
code
code
Sub
code
Title
Black image density sensor trouble
(Transfer belt surface reflection
ratio abnormality)
(Transfer belt surface reflection
ratio abnormality)
F2
44
Display
Lamp/Message
Phenomenon
Detail
Before starting process
control, the transfer belt
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However, when
the sensor gain is changed,
the output is not within the
specified range.
control, the transfer belt
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However, when
the sensor gain is changed,
the output is not within the
specified range.
Section
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
process control sensor
gain.
Case 1
Cause
When "Error" occurs in
SIM 44-2:
1. Dirt/defect of the image
SIM 44-2:
1. Dirt/defect of the image
density sensor
2. Disconnection of the
harness between the
PCU PWB and the
image density sensor
PCU PWB and the
image density sensor
3. Calibration plate
solenoid operation
trouble
trouble
Check &
Remedy
Remedy
1. Clean/replace the
image density sensor.
2. Connect/replace the
harness between the
PCU PWB and the
image density sensor.
PCU PWB and the
image density sensor.
3. Replace the calibration
plate solenoid.
Case 2
Cause
When SIM 44-2 is
completed:
1. Insufficient cleaning of
completed:
1. Insufficient cleaning of
the transfer belt.
Check &
Remedy
Remedy
1. Check the transfer belt
surface.
Main
code
code
Sub
code
Title
Color image density sensor trouble
(Calibration plate surface reflection
ratio abnormality)
(Calibration plate surface reflection
ratio abnormality)
F2
45
Display
Lamp/Message
Phenomenon
Detail
Before starting process
control, the calibration
plate surface is scanned
with the image density
sensor to adjust the sensor
gain so that the output
becomes a fixed value.
However, when the sensor
gain is changed, the output
is not within the specified
range.
control, the calibration
plate surface is scanned
with the image density
sensor to adjust the sensor
gain so that the output
becomes a fixed value.
However, when the sensor
gain is changed, the output
is not within the specified
range.
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
process control sensor
gain.
Case 1
Cause
When "Error" occurs in
SIM 44-2:
1. Dirt/defect of the image
SIM 44-2:
1. Dirt/defect of the image
density sensor
2. Disconnection of the
harness between the
PCU PWB and the
image density sensor
PCU PWB and the
image density sensor
Check &
Remedy
Remedy
1. Clean/replace the
image density sensor.
2. Connect/replace the
harness between the
PCU PWB and the
image density sensor.
PCU PWB and the
image density sensor.
Case 2
Cause
When SIM 44-2 is
completed:
1. Dirt on the calibration
completed:
1. Dirt on the calibration
plate, calibration plate
solenoid operation
trouble
solenoid operation
trouble
Check &
Remedy
Remedy
1. Clean the calibration
plate. Replace the
calibration plate
solenoid.
calibration plate
solenoid.
Main
code
code
Sub
code
Title
Process humidity sensor
breakdown
breakdown
F2
58
Display
Lamp/Message
Phenomenon
Detail
Process humidity sensor
open
open
Section
Process
Case 1
Cause
Process humidity sensor
harness disconnection
harness disconnection
Check &
Remedy
Remedy
Check connection of the
process humidity sensor
harness.
process humidity sensor
harness.
Case 2
Cause
Process humidity sensor
trouble
trouble
Check &
Remedy
Remedy
Replace the process
humidity sensor.
humidity sensor.
Case 3
Cause
PCU PWB trouble
Check &
Remedy
Remedy
Replace the PCU PWB.