AR-C170 (serv.man28). Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 17

Read Sharp AR-C170 (serv.man28) Service Manual online

AR-C170M  TROUBLESHOOTING  11 - 17
Main 
code
Sub 
code
Title
Half-tone process control 2nd 
patch error (Magenta)
F2
86
Display
Lamp/Message
Phenomenon Detail
2nd step of execution of 
half-tone process control.
When connecting the 
approximation formula (the 
relationship of sensor 
output ratios for the print 
gradation values) in the low-
density section and that in 
the high-density section 
obtained from the patch 
print result, DUTY1 for 20% 
of output ratio in the low-
density section is greater 
than DUTY2 for 25% of 
output ratio in the high-
density section.
<The trouble is saved in the 
trouble history, but F2 
trouble is not displayed. The 
operation is made with the 
previous correction value.>
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain.
Case 1
Cause
When "Error" occurs in the 
gain adjustment of SIM 44-
2:
1. Disconnection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Image density sensor 
dirt/trouble.
Check & 
Remedy
1. Check connection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Clean/replace the image 
density sensor.
Case 2
Cause
When SIM 44-2 gain 
adjustment is completed:
Insufficient cleaning of the 
transfer belt, calibration 
plate solenoid operation 
trouble
Check & 
Remedy
Check the drum surface 
and the belt surface.
Main 
code
Sub 
code
Title
Half-tone process control 2nd 
patch error (Yellow)
F2
87
Display
Lamp/Message
Phenomenon Detail
2nd step of execution of 
half-tone process control.
When connecting the 
approximation formula (the 
relationship of sensor 
output ratios for the print 
gradation values) in the low-
density section and that in 
the high-density section 
obtained from the patch 
print result, DUTY1 for 20% 
of output ratio in the low-
density section is greater 
than DUTY2 for 25% of 
output ratio in the high-
density section.
<The trouble is saved in the 
trouble history, but F2 
trouble is not displayed. The 
operation is made with the 
previous correction value.>
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain.
Case 1
Cause
When "Error" occurs in the 
gain adjustment of SIM 44-
2:
1. Disconnection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Image density sensor 
dirt/trouble.
Check & 
Remedy
1. Check connection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Clean/replace the image 
density sensor.
Case 2
Cause
When SIM 44-2 gain 
adjustment is completed:
Insufficient cleaning of the 
transfer belt, calibration 
plate solenoid operation 
trouble
Check & 
Remedy
Check the drum surface 
and the belt surface.