AR-C170 (serv.man28). Troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 14

Read Sharp AR-C170 (serv.man28) Service Manual online

AR-C170M  TROUBLESHOOTING  11 - 14
Main 
code
Sub 
code
Title
Developing unit CRUM trouble 
(Yellow)
F2
77
Display
Lamp/Message
Phenomenon Detail
CRUM read/write error
Section
Developing
Case 1
Cause
Improper connection or 
disconnection of the 
connector and the harness 
between the PCU and the 
CRUM.
Check & 
Remedy
Check the connector and 
the harness between the 
PCU and the CRUM.
Case 2
Cause
Developing unit trouble
Check & 
Remedy
Replace the developing 
unit.
Case 3
Cause
Control PWB (PCU) trouble
Check & 
Remedy
Replace the PCU PWB.
Main 
code
Sub 
code
Title
Trouble of image density sensor 
for registration (Transfer belt 
surface reflection ratio 
abnormality)
F2
78
Display
Lamp/Message
Phenomenon Detail
Before starting registration, 
the transfer belt surface is 
scanned with the image 
density sensor to adjust the 
sensor gain so that the 
output becomes a fixed 
value. However, when the 
sensor gain is changed, the 
value is not within the 
specified range.
Section
Case 1
Cause
Image density sensor 
trouble, disconnection of 
the harness between the 
PCU PWB and the image 
density sensor, dirt on the 
image density sensor.
Check & 
Remedy
Check the sensor and the 
harness.
Case 2
Cause
Calibration plate solenoid 
operation trouble
Check & 
Remedy
Check the calibration plate 
solenoid operation.
Case 3
Cause
Insufficient cleaning of the 
transfer belt.
Check & 
Remedy
Check the transfer belt 
surface.
Main 
code
Sub 
code
Title
Half-tone process control 1st patch 
error (Black)
F2
80
Display
Lamp/Message
Phenomenon Detail
1st step of execution of half-
tone process control.
The low-density rising point 
or the high-density rising 
point cannot be calculated 
from the linear 
approximation formula of 
the ratio of the sensor 
output for the print 
gradation value obtained 
from the patch print result.
<The trouble is saved in the 
trouble history, but F2 
trouble is not displayed. The 
operation is made with the 
previous correction value.>
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain.
Case 1
Cause
When "Error" occurs in the 
gain adjustment of SIM 44-
2:
1. Disconnection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Image density sensor 
dirt/trouble
Check & 
Remedy
1. Check connection of the 
harness between the 
PCU PWB and the 
image density sensor.
2. Clean/replace the image 
density sensor.
Case 2
Cause
When SIM 44-2 gain 
adjustment is completed:
Insufficient cleaning of the 
transfer belt, calibration 
plate solenoid operation 
trouble
Check & 
Remedy
Check the drum surface 
and the belt surface.
Main 
code
Sub 
code
Title
Half-tone process control 1st patch 
error (Cyan)
F2
81
Display
Lamp/Message
Phenomenon Detail
1st step of execution of half-
tone process control.
The low-density rising point 
or the high-density rising 
point cannot be calculated 
from the linear 
approximation formula of 
the ratio of the sensor 
output for the print 
gradation value obtained 
from the patch print result.
<The trouble is saved in the 
trouble history, but F2 
trouble is not displayed. The 
operation is made with the 
previous correction value.>
Section
Common
Check
Use SIM 44-2 to adjust the 
process control sensor 
gain.