Read Sharp AR-C170 (serv.man28) Service Manual online
AR-C170M TROUBLESHOOTING 11 - 12
Main
code
code
Sub
code
Title
Toner empty sensor abnormality
(Yellow)
(Yellow)
F2
43
Display
Lamp/Message
Phenomenon Detail
Toner empty sensor output
abnormality
abnormality
Section
Cartridge
Case 1
Cause
Connector harness trouble,
connector disconnection
connector disconnection
Check &
Remedy
Remedy
1. Check connection of the
toner empty sensor.
→
Connect it properly.
2. Check connection of the
connector harness to the
PCU PWB.
PCU PWB.
→
Connect it
properly.
3. Check connection of the
cartridge.
→
Connect it
properly.
4. Check for disconnection
of the harness.
→
Replace the harness.
Case 2
Cause
Cartridge trouble
Check &
Remedy
Remedy
Replace the cartridge.
Main
code
code
Sub
code
Title
Black image density sensor trouble
(Transfer belt surface reflection
ratio abnormality)
(Transfer belt surface reflection
ratio abnormality)
F2
44
Display
Lamp/Message
Phenomenon Detail
Before starting process
control, the transfer belt
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However, when
the sensor gain is changed,
the output is not within the
specified range.
control, the transfer belt
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However, when
the sensor gain is changed,
the output is not within the
specified range.
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
process control sensor
gain.
Case 1
Cause
When "Error" occurs in SIM
44-2:
1. Dirt/defect of the image
44-2:
1. Dirt/defect of the image
density sensor
2. Disconnection of the
harness between the
PCU PWB and the
image density sensor
PCU PWB and the
image density sensor
3. Calibration plate
solenoid operation
trouble
trouble
Check &
Remedy
Remedy
1. Clean/replace the image
density sensor.
2. Connect/replace the
harness between the
PCU PWB and the
image density sensor.
PCU PWB and the
image density sensor.
3. Replace the calibration
plate solenoid.
Case 2
Cause
When SIM 44-2 is
completed:
1. Insufficient cleaning of
completed:
1. Insufficient cleaning of
the transfer belt.
Check &
Remedy
Remedy
1. Check the transfer belt
surface.
Main
code
code
Sub
code
Title
Color image density sensor trouble
(Calibration plate surface reflection
ratio abnormality)
(Calibration plate surface reflection
ratio abnormality)
F2
45
Display
Lamp/Message
Phenomenon Detail
Before starting process
control, the calibration plate
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However, when
the sensor gain is changed,
the output is not within the
specified range.
control, the calibration plate
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However, when
the sensor gain is changed,
the output is not within the
specified range.
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
process control sensor
gain.
Case 1
Cause
When "Error" occurs in SIM
44-2:
1. Dirt/defect of the image
44-2:
1. Dirt/defect of the image
density sensor
2. Disconnection of the
harness between the
PCU PWB and the
image density sensor
PCU PWB and the
image density sensor
Check &
Remedy
Remedy
1. Clean/replace the image
density sensor.
2. Connect/replace the
harness between the
PCU PWB and the
image density sensor.
PCU PWB and the
image density sensor.
Case 2
Cause
When SIM 44-2 is
completed:
1. Dirt on the calibration
completed:
1. Dirt on the calibration
plate, calibration plate
solenoid operation
trouble
solenoid operation
trouble
Check &
Remedy
Remedy
1. Clean the calibration
plate. Replace the
calibration plate
solenoid.
calibration plate
solenoid.
Main
code
code
Sub
code
Title
Process humidity sensor
breakdown
breakdown
F2
58
Display
Lamp/Message
Phenomenon Detail
Process humidity sensor
open
open
Section
Process
Case 1
Cause
Process humidity sensor
harness disconnection
harness disconnection
Check &
Remedy
Remedy
Check connection of the
connector and the harness
of the process humidity
sensor.
connector and the harness
of the process humidity
sensor.
Case 2
Cause
Process humidity sensor
trouble
trouble
Check &
Remedy
Remedy
Replace the process
humidity sensor.
humidity sensor.
Case 3
Cause
PCU PWB trouble
Check &
Remedy
Remedy
Replace the PCU PWB.
Click on the first or last page to see other AR-C170 (serv.man28) service manuals if exist.