AR-C170 (serv.man26). Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 29

Read Sharp AR-C170 (serv.man26) Service Manual online

AR-C170M  SIMULATION  9 - 29
(Counters to be cleared)
(Counters to be cleared)
After replacement of the OPC drum, the following counters are 
cleared.
(Counters to be cleared)
1. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
2. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
After removing waste toner from the transfer section, the counter 
is cleared.
24
-4
Purpose
Data clear
Function 
(Purpose)
Used to reset the maintenance counter.
Item
Counter
Maintenance
Operation/
Procedure
1. Press the [EXECUTE] key. The display for 
reconfirmation to clear is shown.
2. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
MAINTE (COL)
Maintenance counter (Color)
MAINTE (ALL)
Maintenance counter (Total)
BELT UNIT
Transfer unit print counter
FUSER UNIT
Fusing unit print counter
24
-6
Purpose
Data clear
Function 
(Purpose)
Used to clear the copy counters.
Item
Counter
Operation/
Procedure
1. Select the counter to be cleared.
2. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
3. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
Display
Content
COPY BW
Copier (B/W) counter
COPY COL
Copier (Color) counter
SINGLE COLOR
Single color
24
-7
Purpose
Data clear
Function 
(Purpose)
Used to clear the OPC drum (membrane decrease) 
correction counter. (This simulation is performed 
with the OPC drum is replaced.)
Section
Process (Photoconductor, 
developing, transfer, cleaning)
Photoconductor
Item
Counter
Photoconductor
Operation/
Procedure
1. Select the counter to be cleared. 
2. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
Display
Content
DRUM CTRG K
Drum cartridge (K)
DRUM CTRG C
Drum cartridge (C)
DRUM CTRG M
Drum cartridge (M)
DRUM CTRG Y
Drum cartridge (Y)
24
-8
Purpose
Data clear
Function 
(Purpose)
Used to clear the waste toner counter in the transfer 
section.
Section
Process (Photoconductor, 
developing, transfer, cleaning)
Transfer
Item
Counter
Operation/
Procedure
In order to execute this simulation, the following 
conditions must be satisfied. Be sure to check them 
in advance.
The transfer unit is installed to the machine.
All the cabinet open/close detection switches are 
ON.