AR-5316E (serv.man3). AR-5316 Service Manual (Supplemental information for AR-5316E and AR-5320E). - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp AR-5316E (serv.man3) Service Manual online

AR-5316/5320 SIMULATIONS 7-3
06
02
Resist roller solenoid operation 
check
When the [START] key is pressed in the sub code input state, the resist solenoid (RRS) turns ON for 
500ms and OFF for 500ms. This operation is repeated 20 times. 
After completion of the process, the machine goes into the sub code input standby mode. 
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input 
standby mode. When [CA] key is pressed, the simulation is terminated.
10
Cassette semi-circular roller 
cleaning
First of all, remove the developer unit. 
Enter the simulation code, specify the cassette to be cleaned with the tray select key, and press 
START button. The main motor rotates to move the cassette semi-circular roller by half circle and 
make the roller face downward. 
After completion of cleaning, when INTERRUPT key is pressed, the machine goes into the sub code 
entry standby mode and the roller returns to the original positions. 
To clean another roller continuously, press INTERRUPT key to return the roller to the original 
position, and execute the simulation again. 
During the operation, the sub code is displayed on the display. 
*
When CA key is pressed, the simulation mode is terminated. 
However, the roller returns to the original position by the initial operation.
08
01
Developing bias output
When the [START] key is pressed, the developing bias signal is turned ON for 30 sec. 
However, to calculate the actual output value is calculated, execute SIM25-01.
After completion of the process, the machine goes into the sub code input standby mode. 
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input 
standby mode. When [CA] key is pressed, the simulation is terminated.
02
Main charger output (Grid = HIGH) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage 
HIGH mode. After completion of the process, the machine goes into the sub code input standby 
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input 
standby mode. When [CA] key is pressed, the simulation is terminated.
03
Main charger output (Grid = LOW) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage 
LOW mode. After completion of the process, the machine goes into the sub code input standby 
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input 
standby mode. When [CA] key is pressed, the simulation is terminated.
06
Transfer charger output
Select an output mode with the [Mode select] key and press the [START] key. The transfer charger 
output is delivered for 30 sec in the selected mode. 
After 30 sec of transfer charger output, the machine goes into the sub code entry standby mode. 
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input 
standby mode. When [CA] key is pressed, the simulation is terminated.
22
01
Maintenance counter display
The maintenance counter value is displayed. (Alternate display by 3 digits)
04
Jam total counter display
The jam total counter value is displayed. (Alternate display by 3 digits)
05
Total counter display
The total counter value is displayed.  (Alternate display by 3 digits)
06
Developing counter display
The developing counter data is acquired and displayed on the 7-seg display.  (Alternate display by 3 
digits)
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
08
SPF counter display 
The SPF counter value is displayed.  (Alternate display by 3 digits)
14
P-ROM version display
The P-ROM version is displayed on the copy quantity display. The main code and the sub code are 
alternatively displayed by 2 digits. The display interval is same as that of the counter display. 
By pressing the fixed magnification ratio key, each version display is switched. 
17
Copy counter display
The copy counter value is displayed. (Alternate display by 3 digits) When the [Interrupt] key is 
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the 
simulation is terminated.
18
Printer counter display
The printer counter value is displayed.  (Alternate display by 3 digits)When the [Interrupt] key is 
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the 
simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed.  (Alternate display by 3 digits)When the [Interrupt] key is 
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the 
simulation is terminated.
Main 
code
Sub 
code
Contents
Details of operation
•Small size is Letter R (A4R) or smaller.
Display lamp
Output mode
AE mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamp 
Normal size width: Front surface
Small size width: Front surface
Manual paper feed mode
Display lamp (AB series)
Display lamp (Inch series)
Displayed version
141%
141%
Machine program
[07]SIMULATIONS.fm  3 ページ  2003年12月19日 金曜日 午後3時26分
Page of 19
Display

Click on the first or last page to see other AR-5316E (serv.man3) service manuals if exist.